Abstract

The gas pressure in the main network of transmission lines is about 700 to 1000 psi (4826.33 to 6894.76 kPa), which is reduced to 250 psi (1723.69 kPa) at the entrance station of a city. This reduction process, which occurs in the regulator, causes a severe drop in gas temperature. The drop in the gas temperature produces hydrates and even causes the water vapor in the gas to freeze. As a result, there is a possibility that the passage of gas in the regulator is blocked and the gas flow is cut off. By employing heaters (indirect water heaters), the temperature of the gas entering the regulator can be preheated to eliminate the possibility of freezing in the regulator. This heater is fueled with natural gas and it operates for 24 hr a day, especially in the cold seasons. Therefore, one of the main challenges in using this type of heater is its high fuel consumption. Consequently, researchers are looking for a solution to reduce the fuel consumption (natural gas) of gas heaters. In this paper, the heat transfer and fluid flow in a heater of a natural gas pressure reduction plant, the Aliabad Power Plant (Iran), are numerically investigated using a commercial Computational Fluid Dynamics (CFD) code, ANSYS FLUENT 18.2. The considered heater consists of three parts, including (i) gas coils, (ii) a water bath (shell), and (iii) a fire tube. The indirect heat transfer process takes place between the hot liquid flow in the fire tube (combustion exhaust) and the cold liquid flow (natural gas) using the natural convection flows generated in the water bath. Numeric modeling is performed for four different gas mass flows, including 6 × 104, 8 × 104, 1 × 105, and 12 × 105 standard cubic meters per hour (or 16.67, 22.22, 27.78, and 33.33 m3/s). The results indicate that the natural gas outlet temperature achieved to a temperature higher than required. By installing a regulator on the burner, the gas consumption can be reduced, resulting in station cost savings, and also reducing the environmental impacts. The outcomes depict that the maximum possible reductions in monthly gas consumption and economic savings in the proposed system are 67,500 m3 and IRR 25 million at a gas mass flow rate of 60,000 SCMH.

Publisher

MDPI AG

Subject

Water Science and Technology,Aquatic Science,Geography, Planning and Development,Biochemistry

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3