Affiliation:
1. College of Safety and Environmental Engineering, Shandong University of Science and Technology, Qingdao 266590, China
Abstract
This paper explores the temperature distribution (TD) and maximum temperature (MT) below the ceiling induced by the ceiling jet of an asymmetric dual fire sources in a naturally ventilated tunnel. Considering strong plumes, this study investigates the effects of fire size and spacing of asymmetric dual fire sources on TD and MT. With the same power of fire source, when the size of one of the fire sources increases, the corresponding maximum temperature beneath ceiling decreases. Additionally, the temperature peak below the ceiling shifts from one to two, and the peak temperature of the larger fire source is lower compared to that of smaller one. When the fire sources distance increases, the maximum temperature initially decreases and then increases. Beyond a certain distance, the maximum temperature no longer changes with increasing distance. In this study, we investigated the effect of fire source size and spacing on the MT of the tunnel ceiling for asymmetric dual fire sources. A new model for predicting the MT underneath the tunnel ceiling was developed, taking into account the factors as fire spacing and fire size. The model is able to make effective predictions of the simulation results.
Funder
National Natural Science Foundation of China
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献