An In Vitro Evaluation of Primary Stability Values for Two Differently Designed Implants to Suit Immediate Loading in Very Soft Bone

Author:

Krischik DirkORCID,Tokgöz Selen ErginORCID,van Orten AndreasORCID,Friedmann AntonORCID,Bilhan HakanORCID

Abstract

The achievement of sufficient implant stability in poor quality bone seems to be a challenge. Most manufacturers develop special dental implants, which are claimed to show higher stability even in very soft bone. The aim of this experimental study was to compare two recently introduced dental implants with differing thread designs. A total of 11 implants of each group were inserted in the part of the fresh bovine ribs, corresponding to very soft bone. The primary stability was measured with resonance frequency analysis (RFA) and Periotest; the average of two measurements for each method and for each implant was taken and statistical analysis was applied. The highest stability values were obtained with the ICX Active Master implants, followed by the Conelog® Progressive-Line implants placed with the very soft bone protocol. The primary stability values of the Conelog® Progressive-Line implants inserted by the very soft bone protocol and the ICX Active Master implants placed with the standard protocol showed sufficient stability for immediate loading in low-density bone. Within the limitations of this study, the thread design of the implants and underdimensioned implant bed preparation seem to be effective for better primary stability in cancellous bone.

Publisher

MDPI AG

Subject

General Dentistry

Reference27 articles.

1. Assessment of implant stability as a prognostic determinant;Meredith;Int. J. Prosthodont.,1998

2. Role of primary stability for successful osseointegration of dental implants: Factors of influence and evaluation;Javed;Interv. Med. Appl. Sci.,2013

3. Effects of implant thread design on primary stability—a comparison between single- and double-threaded implants in an artificial bone model

4. The Evidence for Immediate Loading of Implants

5. Timing of loading and effect of micromotion on bone-dental implant interface: Review of experimental literature

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3