Abstract
A transfer–purge chamber (TPC) is a double-steel-plate, heavy-concrete, curved-surface composite structure composed of steel plates, heavy concrete, and shear connectors. It is an important facility in the external refueling system of a nuclear power plant (NPP), providing a safe and reliable biological shielding space for reactor refueling operations. Temperature load is one of the most important factors that must be considered in the design of NPP structures. The temperature loads experienced by the TPC during its life cycle include those encountered in both normal and abnormal operation, which are distinct. In this study, we investigated the steady state and transient-state temperature fields and stresses of a TPC structure under normal operation and after 48 h of abnormal operation, respectively, which were calculated using Abaqus finite element software and the directly coupled method. During normal operation, the temperature field of the structure shows relatively uniform changes, and the temperature gradient of the internal concrete in the direction of its thickness has a constant value of 0.245 °C/cm. At the junction between the transfer and purge sub-chambers of the TPC, under the influence of wall curvature and deformation constraints, the maximum tensile strain of heavy concrete is 8.84 × 10−3, the maximum compressive strain is 2.04 × 10−3, the peak stress of the steel plate is 98.305 MPa, and the peak stress of the stud is 306.725 MPa. After 48 h of abnormal operation, the temperatures of the inner surface of the heavy concrete of the wall, the inner steel plate of the wall, the outer surface of the heavy concrete of the wall, and the inner steel plate of the wall increased by 8.12, 8.11, 0.31, and 0.30 °C, respectively. The tensile strain of the heavy concrete of the wall increased significantly by 52.64%, and the compressive strain of the concrete increased by 67.33%, whereas the stresses of the studs and steel plates increased by only 1.57% and 6.79%, respectively. These results show that the change in the temperature field greatly influences the stress and strain on the TPC structure. As measures for mitigating the development of this unfavorable situation of temperature stress concentration, the temperature operating range should be rationally controlled or the junction structure between the transfer and purge sub-chambers of the TPC optimized accordingly. The results of our study can provide basic data for a dynamic analysis of the TPC under conditions of combined earthquake and temperature loads.
Funder
National Natural Science Foundation of China
Central research institutes of basic research and public service special operations
Subject
General Materials Science
Reference23 articles.
1. Transient temperature field analysis and simplified design method of civil engineering structures in nuclear power plant;Zhang;Ind. Construct.,2017
2. (2019). Standard No. NB/T 20105-2019.
3. Discussion on analysis methods of various thermal actions in the design of nuclear power plant containment;Zhao;Build. Struct.,2017
4. Yonezawa, K., Imoto, K., Ohba, M., Ikeuchi, T., Kozuma, M., Murazumi, Y., and Sato, K. (2003, January 17–22). Analytical study on structural failure mode of 1/4 PCCV test model. Proceedings of the International Conference on Structural Mechanics in Reactor Technology (SMiRT 17), Prague, Czech Republic.
5. Ultimate capacity analysis of 1/4 PCCV model subjected to internal pressure;Yonezawa;Nuclear Eng. Des.,2002