Structural Integrity of Anterior Ceramic Resin-Bonded Fixed Partial Denture: A Finite Element Analysis Study

Author:

Osman Mas Linda Mohd1,Lim Tong Wah2ORCID,Chang Hung-Chih3,Ab Ghani Amir Radzi4,Tsoi James Kit Hon5ORCID,Ab Ghani Siti Mariam1

Affiliation:

1. Centre of Restorative Dentistry Studies, Faculty of Dentistry, Universiti Teknologi MARA, Sungai Buloh 47000, Selangor, Malaysia

2. Division of Restorative Dental Sciences, Faculty of Dentistry, The University of Hong Kong, Hong Kong SAR, China

3. Department of Biomedical Engineering, Hungkuang University, Taichung City 433304, Taiwan

4. College of Engineering, Universiti Teknologi MARA, Shah Alam 40450, Selangor, Malaysia

5. Division of Applied Oral Sciences and Community Dental Care, Faculty of Dentistry, The University of Hong Kong, Hong Kong SAR, China

Abstract

This study was conducted as a means to evaluate the stress distribution patterns of anterior ceramic resin-bonded fixed partial dentures derived from different materials and numerous connector designs that had various loading conditions imposed onto them through the utilization of the finite element method. A finite element model was established on the basis of the cone beam computed tomography image of a cantilevered resin-bonded fixed partial denture with a central incisor as an abutment and a lateral incisor as a pontic. Sixteen finite element models representing different conditions were simulated with lithium disilicate and zirconia. Connector height, width, and shape were set as the geometric parameters. Static loads of 100 N, 150 N, and 200 N were applied at 45 degrees to the pontic. The maximum equivalent stress values obtained for all finite element models were compared with the ultimate strengths of their materials. Higher load exhibited greater maximum equivalent stress in both materials, regardless of the connector width and shape. Loadings of 200 N and 150 N that were correspondingly simulated on lithium disilicate prostheses of all shapes and dimensions resulted in connector fractures. On the contrary, loadings of 200 N, 150 N, and 100 N with rectangular-shaped connectors correspondingly simulated on zirconia were able to withstand the loads. However, two of the trapezoidal-shaped zirconia connectors were unable to withstand the loads and resulted in fractures. It can be deduced that material type, shape, and connector dimensions concurrently influenced the integrity of the bridge.

Funder

Universiti Teknologi MARA DUCS

Publisher

MDPI AG

Subject

Biomedical Engineering,Biomaterials

Reference50 articles.

1. Resin bonded bridges;Lim;Malays. Dent. J.,2014

2. Fifteen-year survival of resin-bonded vs full-coverage fixed dental prostheses;Yoshida;J. Prosthodont. Res.,2019

3. Current ceramic materials and systems with clinical recommendations: A systematic review;Conrad;J. Prosthet. Dent.,2007

4. Tooth structure removal associated with various preparation designs for anterior teethD;Edelhoff;J. Prosthet. Dent.,2002

5. Dental implants: The last 100 years;Block;J. Oral Maxillofac. Surg.,2018

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3