Abstract

Sedentary behaviors and low physical activity among hospitalized patients have detrimental effects on health and recovery. Wearable activity monitors are a promising tool to promote mobilization and physical activity. However, existing devices have limitations in terms of their outcomes and validity. The Activ8 device was optimized for the hospital setting. This study assessed the concurrent validity of the modified Activ8. Hospital patients performed an activity protocol that included basic (e.g., walking) and functional activities (e.g., room activities), with video recordings serving as the criterion method. The assessed outcomes were time spent walking, standing, upright, sedentary, and newly added elements of steps and transfers. Absolute and relative time differences were calculated, and Wilcoxon and Bland–Altman analyses were conducted. Overall, the observed relative time differences were lower than 2.9% for the basic protocol and 9.6% for the functional protocol. Statistically significant differences were detected in specific categories, including basic standing (p < 0.05), upright time (p < 0.01), and sedentary time (p < 0.01), but they did not exceed the predetermined 10% acceptable threshold. The modified Activ8 device is a valid tool for assessing body postures, motions, steps, and transfer counts in hospitalized patients. This study highlights the potential of wearable activity monitors to accurately monitor and promote PA among hospital patients.

Publisher

MDPI AG

Subject

Electrical and Electronic Engineering,Biochemistry,Instrumentation,Atomic and Molecular Physics, and Optics,Analytical Chemistry

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3