A Novel Personalized Strategy for Hip Joint Flexion Assistance Based on Human Physiological State

Author:

Wu Beixian123,Chen Chunjie234ORCID,Wang Sheng23,Chen Hui23,Wang Zhuo23ORCID,Liu Yao23,He Tingwei23,Zhang Jiale1,Wu Xinyu234

Affiliation:

1. College of Mechanical and Control Engineering, Guilin University of Technology, Guilin 541006, China

2. ShenZhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, China

3. Guangdong Provincial Key Lab of Robotics and Intelligent System, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, China

4. Guangdong-Hong Kong-Macao Joint Laboratory of Human-Machine Intelligence-Synergy Systems, Shenzhen 518055, China

Abstract

Soft exosuits have emerged as potent assistive tools for walking support and rehabilitation training. However, most existing soft exosuit systems rely on preset assistance modes, which may not accurately align with individual physiological states and movement requirements, leading to variable user experiences and efficacy. While existing human-in-the-loop (HIL) research predominantly focuses on optimizing metabolic cost and torque difference parameters, there is a notable absence of real-time monitoring methods that closely reflect the human body’s physiological state and strategies that dynamically indicate walking efficiency. Motivated by this, we developed a novel personalized power-assist system. This system optimizes the power-assist output of the hip joint by monitoring the user’s physiological and motion signals in real time, including heart rate (HR), blood oxygen saturation (SpO2), and inertial measurement unit (IMU) data, to assist hip flexion based on feedback. The findings from a metabolic expenditure trial demonstrate that the innovative soft exosuit, which is based on a Physiological State Monitoring Control (PSMC) system, achieves a reduction of 7.81% in metabolic expenditure during treadmill walking at a speed of 3.5 km/h compared to walking without the assistance of the exosuit. Additionally, during continuous exercise with varying intensities, the metabolic consumption level is reduced by 5.1%, 5.8%, and 8.2% at speeds of 2, 4, and 6 km per hour, respectively. These results support the design of a novel hip flexion-assisting soft exosuit, demonstrating that applying different assistance forces in consideration of different physiological states is a reasonable approach to reducing metabolic consumption.

Funder

National Key R&D Program of China

NSFC-Shenzhen Robotics Research Center Project

Natural Science Foundation of China

Natural Science Foundation of Guangdong Province

SIAT-CUHK Joint Laboratory of Robotics and Intelligent System

Publisher

MDPI AG

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3