Alternative Internal Configurations for Enhancing Heat Transfer in Telecommunication Cabinets

Author:

Jobby Antony1ORCID,Khatamifar Mehdi1ORCID,Lin Wenxian1ORCID

Affiliation:

1. College of Science & Engineering, James Cook University, Townsville, QLD 4811, Australia

Abstract

Telecommunication systems have become a critical part of society which enables connectivity to many essential and trivial services. Consequently, telecommunication equipment is housed in cabinets to protect the electronics from a variety of hazards; one of which is temperature-related failure. Current practices use a notable amount of power for the thermal management of telecommunication cabinets which can be reduced by considering alternative methods of cooling. In this paper, experiments were carried out to investigate the effectiveness of different internal mounting configurations of electronic components on the thermal performance of a telecommunication cabinet. The investigation tested inclinations (0–90°), different staggered offsets (0–50 mm), changing stream-wise spacing (29–108 mm), and fan speed (with a Reynolds number in the range of 1604 to 5539). The experimental study revealed that heat transfer was enhanced by 9.99% by altering component inclination to 90°, 25.90% by increasing stream-wise spacing from 29 mm to 108 mm, and 36.02% by increasing the Reynolds number from 1604 to 5539. However, the staggered arrangement of internal components decreased Nu by 3.26% for the natural convection condition but increased by 5.69% for the forced convection condition over the tested range and increasing the centre offset of the staggered components with respect to the cabinet did not influence Nu in any significant manner. Natural convection and forced convection also had notable influence on the heat transfer rate. Hence it was seen that alternative internal configurations positively influence heat transfer in telecommunication cabinets for the cases studied.

Publisher

MDPI AG

Subject

Energy (miscellaneous),Energy Engineering and Power Technology,Renewable Energy, Sustainability and the Environment,Electrical and Electronic Engineering,Control and Optimization,Engineering (miscellaneous),Building and Construction

Reference42 articles.

1. Experimental study and numerical simulation of the interior flow in a telecommunications cabinet;Delgado;Energy Procedia,2017

2. Le Masson, S., Chehade, A.A., and Louahlia-Gualous, H. (2013, January 13–17). Passive cooling of telecommunication outdoor cabinets for mobile base station. Proceedings of the 35th International Telecommunications Energy Conference, Smart Power and Efficiency (INTELEC), Hamburg, Germany.

3. Heat transfer from a surface fitted with rectangular blocks at different orientation angle;Bilen;Heat Mass Transf.,2002

4. Two-phase thermosyphon loop for cooling outdoor telecommunication equipments;Samba;Appl. Therm. Eng.,2013

5. Louahlia-Gualous, H., and Le Masson, S. (2016, January 23–27). Experimental and theoretical investigations of a telecommunication cabinet cooling mode with zero electrical consumption. Proceedings of the 2016 IEEE International Telecommunications Energy Conference (INTELEC), Austin, TX, USA.

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3