Upgrades in building energy efficiency codes led to differences between buildings designed according to outdated codes and those with most recent requirements. In this context, our study investigates the influence of external wall thermal transmittance, thermal inertia, and orientation on energy demand (heating, cooling) and occupant thermal comfort. Simulation models of an office building were designed, varying (i) the thermal transmittance values (0.20 and 0.60 W/(m2K)), (ii) the room orientation (four cardinal directions), and (iii) the wall thermal inertia (approximately 60 kJ/(m2K) for low and 340 kJ/(m2K) for high thermal inertia. The energy demand for heating and cooling seasons was calculated for Ljubljana using EnergyPlus 9.0.0 software. The reduction of the external wall thermal transmittance value from 0.6 W/(m2K) to 0.2 W/(m2K) contributes to significant energy savings (63% for heating and 37% for cooling). Thermal inertia showed considerable potential for energy savings, especially in the cooling season (20% and 13%, depending on the external wall insulation level). In addition, the orientation proved to have a notable impact on heating and cooling demand, however not as pronounced as thermal inertia (up to 7% total energy demand). Comparison of the thermal comfort results showed that when internal air temperatures are identically controlled in all the rooms (i.e., internal air temperature is not an influencing factor), the external wall thermal transmittance, thermal inertia, and room orientation show negligible influence on the average occupant thermal comfort. The simultaneous achievement of thermally comfortable conditions in the working environment and low energy use can only be achieved by simultaneously considering the U-value and thermal inertia.

Funder

Slovenian Research Agency

Publisher

MDPI AG

Subject

Energy (miscellaneous),Energy Engineering and Power Technology,Renewable Energy, Sustainability and the Environment,Electrical and Electronic Engineering,Control and Optimization,Engineering (miscellaneous),Building and Construction

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3