PPG-Based Systolic Blood Pressure Estimation Method Using PLS and Level-Crossing Feature

Author:

Fujita DaisukeORCID,Suzuki Arata,Ryu Kazuteru

Abstract

This paper proposes a cuff-less systolic blood pressure (SBP) estimation method using partial least-squares (PLS) regression. Level-crossing features (LCFs) were used in this method, which were extracted from the contour lines arbitrarily drawn on the second-derivative photoplethysmography waveform. Unlike conventional height ratio features (HRFs), which are extracted on the basis of the peaks in the waveform, LCFs can be reliably extracted even if there are missing peaks in the waveform. However, the features extracted from adjacent contour lines show similar trends; thus, there is a strong correlation between the features, which leads to multicollinearity when conventional multiple regression analysis (MRA) is used. Hence, we developed a multivariate estimation method based on PLS regression to address this issue and estimate the SBP on the basis of the LCFs. Two-hundred-and-sixty-five subjects (95 males and 170 females [(Mean ± Standard Deviation) SBP: 133.1 ± 18.4 mmHg; age: 62.8 ± 16.8 years] participated in the experiments. Of the total number of subjects, 180 were considered as learning data, while 85 were considered as testing data. The values of the correlation coefficient between the measured and estimated values were found to be 0.78 for the proposed method (LCFs + PLS), 0.58 for comparison method 1 (HRFs + MRA), and 0.62 for comparison method 2 (HRFs + MRA). The proposed method was therefore found to demonstrate the highest accuracy among the three methods being compared.

Publisher

MDPI AG

Subject

Fluid Flow and Transfer Processes,Computer Science Applications,Process Chemistry and Technology,General Engineering,Instrumentation,General Materials Science

Reference21 articles.

1. Non-invasive continuous blood pressure measurement based on mean impact value method, BP neural network, and genetic algorithm

2. Cuffless blood pressure estimation using pulse transit time and photoplethysmogram intensity ratio;Gholamhosseini;Stud. Health Technol. Inform.,2018

3. Optical blood pressure estimation with photoplethysmography and FFT-based neural networks;Xiaoman;Biomed. Opt.,2016

Cited by 33 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3