Abstract
Antimony (Sb) is classified as a toxic pollutant of high priority, because its effects on human health (toxicity) are similar to those of arsenic. However, unlike arsenic, the removal of antimony from polluted waters is still not well understood. In the present study the removal of common antimony species in water, namely, Sb(III) and Sb(V), was investigated by the addition of iron-based coagulants. The applied coagulants were Fe(II), Fe(III), and equimolar mixed Fe(II)/Fe(III) salts and the experiments were performed with realistic antimony concentrations in the range 10–100 μg/L, by using artificially polluted tap water solutions. Sb(III) removal by Fe(III) provided better adsorption capacity at a residual concentration equal to the drinking water regulation limit of 5 μg/L, that is, Q5 = 4.7 μg Sb(III)/mg Fe(III) at pH 7, which was much higher than the value achieved by the addition of Fe(II) salts, that is, Q5 = 0.45 μg Sb(III)/mg Fe(II), at the same pH value. Similarly, Sb(V) was more efficiently removed by Fe(III) addition, than by the other examined coagulants. However, Fe(III) uptake capacity for Sb(V) was found to be significantly lower, that is, Q5 = 1.82 μg Sb(V)/mg Fe(III), than the corresponding value for Sb(III). The obtained results can give a realistic overview of the efficiency of conventionally used iron-based coagulants and of their mixture for achieving Sb concentrations below the respective drinking water regulation limit and therefore, they can be subsequently applied for the designing of real-scale water treatment units.
Subject
Water Science and Technology,Aquatic Science,Geography, Planning and Development,Biochemistry
Cited by
26 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献