Fracture Resistance of CAD/CAM Implant-Supported 3Y-TZP-Zirconia Cantilevers: An In Vitro Study

Author:

Novais Mariana,Silva António SérgioORCID,Mendes JoanaORCID,Barreiros PedroORCID,Aroso CarlosORCID,Mendes José ManuelORCID

Abstract

(1) Introduction: Implant-supported fixed complete dentures are mostly composed of cantilevers. The purpose of this work was to evaluate the fracture resistance of zirconia (Prettau®, second generation, or Ice Zirkon Translucent, first generation) with cantilever lengths of 6 and 10 mm, and zirconia’s fracture resistance in relation to an average bite force of 250 N. (2) Materials and methods: Forty structures were created in CAD/CAM and divided into four groups: group A (6 mm cantilever in IZT), group B (10 mm cantilever in IZT), group C (6 mm cantilever in Pz), and group D (10 mm cantilever in pz). The study consisted of a traditional “load-to-failure” test. (3) Results: A statistically significant result was found for the effect of cantilever length, t(38) = 16.23 (p < 0.001), with this having a large effect size, d = 4.68. The 6 mm cantilever length (M = 442.30, sd = 47.49) was associated with a higher mean force at break than the 10 mm length (M = 215.18, sd = 40.74). No significant effect was found for the type of zirconia: t(38) = 0.31 (p = 0.757), and d = 0.10. (4) Conclusions: All the components with cantilever lengths of 6 mm broke under forces higher than 250 N. Cantilevers larger than 10 mm should be avoided.

Publisher

MDPI AG

Subject

General Materials Science

Reference38 articles.

1. Global oral health of older people–call for public health action;Petersen;Community Dent Health,2010

2. Unconventional implants for distal cantilever fixed full-arch prostheses: A long-term evaluation of four cases;Minoretti;Int. J. Periodontics Restor. Dent.,2012

3. Retention Capacity of Original Denture Adhesives and White Brands for Conventional Complete Dentures: An In Vitro Study

4. Implant-Supported Fixed Dental Prostheses with CAD/CAM-Fabricated Porcelain Crown and Zirconia-Based Framework

5. Fracture load of complete-arch implant-supported prostheses reinforced with nylon-silica mesh: An in vitro study

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3