This retrospective study completed at a tertiary care center aimed to assess the monothermal caloric test (MCT) as a screening test, using the bithermal caloric test (BCT) as a reference. Additionally, it attempts to measure the sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of a fixed inter-auricular difference (IAD) value for both cold and warm stimuli using water irrigation. Medical records of 259 patients referred for vestibular symptoms who underwent BCT with water irrigation were reviewed. Patients with bilateral vestibular weakness and caloric tests using air irrigation were excluded. BCT showed 40.9% unilateral weakness. Two formulas were used to determine the monothermal caloric asymmetry (MCA-1 and MCA-2). The measurement of agreement Kappa between the two formulas in comparison with BCT revealed moderate agreement at 0.54 and 0.53 for hot and cold stimulation, respectively. The monothermal warm stimulating test (MWST) using MCA-2 showed better results, with a sensitivity of 80%, specificity of 91%, PPV of 83.1%, and NPV of 89.2%. Thirty-four patients had horizontal spontaneous nystagmus (HSN) with a mean velocity of 2.25°/s. These patients showed better sensitivity but lower specificity after adjustment of HSN using the MCA-2 formula at warm temperatures. Therefore, they should complete the caloric test with cold irrigation to perform the BCT. MCT is efficient as a screening test if the warm stimulus is used with the MCA-2 formula fixed at 25%. If present, HSNs should be adjusted. Negative IAD (normal) in the absence or presence of adjusted HSN or slow-phase eye velocity ≤ 6°/s at each right and left warm stimulation should be accomplished by the BCT.

Publisher

MDPI AG

Subject

General Medicine

Reference22 articles.

1. Clinical nystagmography;Jongkees;Pract. Otorhinolaryngol.,1962

2. Video head impulse test: A review of the literature;Alhabib;Eur. Arch. Otorhinolaryngol.,2017

3. Clinical evaluation of the hot caloric test as a screening procedure;Dayal;Laryngoscope,1973

4. Diagnostic Advantages of the Torok Monothermal Differential Caloric Test;Kumar;Laryngoscope,1981

5. The derivation of optimum criteria for use in the monothermal caloric screening test;Lightfoot;Ear Hear.,2009

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3