Esophageal Protection and Temperature Monitoring Using the Circa S-Cath™ Temperature Probe during Epicardial Radiofrequency Ablation of the Pulmonary Veins and Posterior Left Atrium

Author:

Kronenberger RaniORCID,Parise OrlandoORCID,Van Loo Ines,Gelsomino SandroORCID,Welch Ashley,De Asmundis CarloORCID,La Meir Mark

Abstract

Although epicardial bipolar radiofrequency ablation should diminish the risk of esophageal thermal injury in comparison to an endocardial ablation, cases of lethal atrio-esophageal fistula have been reported. To better understand this risk and to reduce the possibility of a thermal injury, we monitored the esophageal temperature with the Circa S-Cath™ temperature probe during and immediately after the ablation while implementing three procedural safety measures. Twenty patients (15 males; 63 ± 10 years) were prospectively enrolled (November 2019–February 2021). All patients underwent an epicardial ablation procedure, including an antral left and right pulmonary vein isolation with bidirectional bipolar clamping, and a roof and inferior line using unidirectional bipolar radiofrequency. Three procedural preventive mitigations were implemented: (1) transesophageal echocardiographic visualization of the atrio-esophageal interface, with probe retraction before the energy delivery; (2) lifting the ablated tissue away from the esophagus during an energy application; and (3) a 30 s cool-off and irrigation period after the energy delivery. The esophageal temperature was recorded using an insulated multisensory intraluminal esophageal temperature probe (Circa S-Cath™). Of the 20 patients enrolled, 7 patients had paroxysmal atrial fibrillation (AF), 8 persistent AF and 5 longstanding persistent AF. The average maximum luminal esophageal temperature observed was 36.2 ± 0.7 °C (34.8–38.2 °C). In our clinical experience, no abrupt increase in the luminal esophageal temperature above the baseline was observed. Since no measurements exceeded the threshold of 39 °C, no prompt interruption of energy delivery was required. Intraluminal esophageal temperature monitoring is feasible and can be helpful in confirming correct catheter position and safe energy application in bipolar epicardial left atrial ablation. Intra-procedural preventive mitigations should be implemented to reduce the risk of esophageal temperature rises.

Publisher

MDPI AG

Subject

General Medicine

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3