Abstract
Ablation of pulmonary veins has emerged as a key procedure for normal rhythm restoration in atrial fibrillation patients. However, up to half of ablated Atrial fibrillation (AF) patients suffer recurrences during the first year. In this article, simultaneous intra-atrial recordings registered at pulmonary veins previous to the ablation procedure were analyzed. Spatial cross-correlation and transfer entropy were computed in order to estimate spatial organization. Results showed that, in patients with arrhythmia recurrence, pulmonary vein electrical activity was less correlated than in patients that maintained sinus rhythm. Moreover, correlation function between dipoles showed higher delays in patients with AF recurrence. Results with transfer entropy were consistent with spatial cross-correlation measurements. These results show that arrhythmia drivers located at the pulmonary veins are associated with a higher organization of the electrical activations after the ablation of these sites.
Subject
General Mathematics,Engineering (miscellaneous),Computer Science (miscellaneous)
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献