Abstract
A design scheme of multi-element sensor which included electrical resistivity probes, multiple Cl− selective electrodes, and a steel corrosion monitoring system was proposed in this work. Embedding this multi-element sensor in concrete enables the real-time and non-destructive monitoring of internal electrical resistivity, free Cl− (Clf) contents in the concrete pore solution at different depths, and steel corrosion parameters. Based on the monitoring data obtained by the multi-element sensor, the freezing-thawing (F-T) damage degree, the Clf diffusion coefficient, the quantitative relation between F-T damage degree and Clf diffusion coefficient, the initiation period of steel corrosion, and the critical content related to steel corrosion are determined. To conclude, the multi-element sensor provides key durability parameters for the establishment of the Clf diffusion model, the assessment of health condition, and the prediction of service life of concrete under the coexistence of the F-T cycle and Cl−.
Funder
Jiangsu Planned Projects for Postdoctoral Research Funds
Subject
Electrical and Electronic Engineering,Biochemistry,Instrumentation,Atomic and Molecular Physics, and Optics,Analytical Chemistry
Cited by
9 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献