Evaluation of Low-Cost CO2 Sensors Using Reference Instruments and Standard Gases for Indoor Use

Author:

Cai Qixiang12ORCID,Han Pengfei34ORCID,Pan Guang5,Xu Chi6,Yang Xiaoyu5,Xu Honghui7,Ruan Dongde8,Zeng Ning910

Affiliation:

1. State Key Laboratory of Numerical Modeling for Atmospheric Sciences and Geophysical Fluid Dynamics, Institute of Atmospheric Physics, Chinese Academy of Sciences, Beijing 100029, China

2. Qiluzhongke Institute of Carbon Neutrality, Jinan 250100, China

3. State Key Laboratory of Atmospheric Environment and Extreme Meteorology, Institute of Atmospheric Physics, Chinese Academy of Sciences, Beijing 100029, China

4. Carbon Neutrality Research Center, Institute of Atmospheric Physics, Chinese Academy of Sciences, Beijing 100029, China

5. Shandong Jinan Ecological and Environmental Monitoring Center, Jinan 250102, China

6. State Environmental Protection Key Laboratory of Quality Control in Environmental Monitoring, China National Environmental Monitoring Centre, Beijing 100012, China

7. Zhejiang Lin’an Atmospheric Background National Observation and Research Station, Hangzhou 311300, China

8. Zhejiang Hangzhou Ecological and Environmental Monitoring Center, Hangzhou 310012, China

9. Department of Atmospheric and Oceanic Science, University of Maryland, College Park, MD 20742, USA

10. Earth System Science Interdisciplinary Center, University of Maryland, College Park, MD 20742, USA

Abstract

CO2 monitoring is important for carbon emission evaluation. Low-cost and medium-precision sensors (LCSs) have become an exploratory direction for CO2 observation under complex emission conditions in cities. Here, we used a calibration method that improved the accuracy of SenseAir K30 CO2 sensors from ±30 ppm to 0.7–4.0 ppm for a CO2-monitoring instrument named the SENSE-IAP, which has been used in several cities, such as in Beijing, Jinan, Fuzhou, Hangzhou, and Wuhan, in China since 2017. We conducted monthly to yearly synchronous observations using the SENSE-IAP along with reference instruments (Picarro) and standard gas to evaluate the performance of the LCSs for indoor use with relatively stable environments. The results show that the precision and accuracy of the SENSE-IAP compared to the standard gases were rather good in relatively stable indoor environments, with the short-term (daily scale) biases ranging from −0.9 to 0.2 ppm, the root mean square errors (RMSE) ranging from 0.7 to 1.6 ppm, the long-term (monthly scale) bias ranging from −1.6 to 0.5 ppm, and the RMSE ranging from 1.3 to 3.2 ppm. The accuracy of the synchronous observations with Picarro was in the same magnitude, with an RMSE of 2.0–3.0 ppm. According to our evaluation, standard instruments or reliable standard gases can be used as a reference to improve the accuracy of the SENSE-IAP. If calibrated daily using standard gases, the bias of the SENSE-IAP can be maintained within 1.0 ppm. If the standard gases are hard to access frequently, we recommend a calibration frequency of at least three months to maintain an accuracy within 3 ppm.

Funder

Ministry of Science and Technology of the People’s Republic of China

China Quality Certification Center

Jinan Municipal Bureau of Ecology and Environment

Qilu Zhongke Carbon Neutrality Research Institute

Zhihui Zhongke (Beijing) Technology Co., Ltd.

Science Technology Department of Zhejiang Province

Publisher

MDPI AG

Reference39 articles.

1. Measuring the Carbon Emissions of Megacities;Duren;Nat. Clim. Chang.,2012

2. Masson-Delmotte, V., Zhai, P., Pörtner, H.-O., Roberts, D., Skea, J., Shukla, P.R., Pirani, A., Moufouma-Okia, W., Péan, C., and Pidcock, R. (2018). Global Warming of 1.5 °C. An IPCC Special Report on the Impacts of Global Warming of 1.5 °C above Pre-Industrial Levels and Related Global Greenhouse Gas Emission Pathways, in the Context of Strengthening the Global Response to the Threat of Climate Change, Sustainable Development, and Efforts to Eradicate Poverty, Cambridge University Press.

3. Greenhouse Gas Observations from the Northeast Corridor Tower Network;Karion;Earth Syst. Sci. Data,2020

4. Diurnal, Synoptic and Seasonal Variability of Atmospheric CO2 in the Paris Megacity Area;Vuillemin;Atmos. Chem. Phys.,2018

5. Carbon Dioxide and Methane Measurements from the Los Angeles Megacity Carbon Project—Part 1: Calibration, Urban Enhancements, and Uncertainty Estimates;Verhulst;Atmos. Chem. Phys.,2017

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3