Affiliation:
1. University of Coimbra, Research Unit for Sport and Physical Activity (CIDAF), Faculty of Sport Sciences and Physical Education, 3040-248 Coimbra, Portugal
Abstract
In recent years, there has been an exponential increase in the number of devices developed to measure or estimate physical exercise. However, before these devices can be used in a practical and research environment, it is necessary to determine their validity and reliability. The purpose of this study is to test the validity and reliability of a load cell sensor-based device (LC) for measuring the peak force (PFr) and the rate of force development (RFD) during the isometric mid-thigh pull (IMTP) test, using a force plate (FP) as the gold standard. Forty-two undergraduate sport science students (male and female) participated in this study. In a single session, they performed three repetitions of the IMTP test, being tested simultaneously with an LC device and a Kistler force platform (FP). The PFr and RFD data were obtained from the force-time curve of the FP and compared with the LC data, provided automatically by the software of the device (Smart Traction device©). The mean difference between the results obtained by the LC device and the gold-standard equipment (FP) was not significantly different (p > 0.05), for both PFr and RFD, which suggests the validity of the ST results. Bland–Altman analysis showed a small mean difference in PFr = 1.69 N, upper bound = 47.88 N, and lower bound = −51.27 N. RFD showed that the mean difference was −5.27 N/s, upper limit = 44.36 N/s, and lower limit = −54.91 N/s. Our results suggest that the LC device can be used in the assessment of the isometric-mid-thigh-pull test as a valid and reliable tool. It is recommended that this device’s users consider these research results before putting the ST into clinical practice.
Subject
Electrical and Electronic Engineering,Biochemistry,Instrumentation,Atomic and Molecular Physics, and Optics,Analytical Chemistry
Reference29 articles.
1. Scaling isometric mid-thigh pull maximum strength in division I Athletes: Are we meeting the assumptions?;Suchomel;Sports Biomech.,2020
2. Normalization of Early Isometric Force Production as a Percentage of Peak Force During Multijoint Isometric Assessment;Comfort;Int. J. Sports Physiol. Perform.,2019
3. Use of an isometric mid-thigh pull test during musculoskeletal rehabilitation: Can the criterion values from the updated British Army physical employment standards be used to inform UK Defence Rehabilitation practice?;Walters;BMJ Mil. Health,2022
4. The importance of isometric maximum strength and peak rate-of-force development in sprint cycling;Stone;J. Strength Cond. Res.,2004
5. Dos’Santos, T., Thomas, C., Comfort, P., McMahon, J.J., and Jones, P.A. (2017). Relationships between Isometric Force-Time Characteristics and Dynamic Performance. Sports, 5.
Cited by
2 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献