Author:
Arigi Awwal Mohammed,Park Gayoung,Kim Jonghyun
Abstract
Advancements in the nuclear industry have led to the development of fully digitized main control rooms (MCRs)—often termed advanced MCRs—for newly built nuclear power plants (NPPs). Diagnosis is a major part of the cognitive activity in NPP MCRs. Advanced MCRs are expected to improve the working environment and reduce human error, especially during the diagnosis of unexpected scenarios. However, with the introduction of new types of tasks and errors by digital MCRs, a new method to analyze the diagnosis errors in these new types of MCRs is required. Task analysis for operator diagnosis in an advanced MCR based on emergency operation was performed to determine the error modes. The cause-based decision tree (CBDT) method—originally developed for analog control rooms—was then revised to a modified CBDT (MCBDT) based on the error mode categorizations. This work examines the possible adoption of the MCBDT method for the evaluation of diagnosis errors in advanced MCRs. We have also provided examples of the application of the proposed method to some common human failure events in emergency operations. The results show that with some modifications of the CBDT method, the human reliability in advanced MCRs can be reasonably estimated.
Funder
Multi-Unit Risk Research Group(MURRG), Republic of Korea
Subject
Energy (miscellaneous),Energy Engineering and Power Technology,Renewable Energy, Sustainability and the Environment,Electrical and Electronic Engineering,Control and Optimization,Engineering (miscellaneous)
Cited by
3 articles.
订阅此论文施引文献