Effect of Contact Lens Design on Objective Visual Acuity-Based Parameters in Pre-Presbyopic Patients in Photopic and Mesopic Lighting Conditions

Author:

Sztrigler-Cohen Orit1,Bromberger Nogah1,Thee Yonina1,Lender Rivkah12,Ben-Eli Hadas12

Affiliation:

1. Department of Optometry and Vision Science, Hadassah Academic College, Jerusalem 91010, Israel

2. Department of Ophthalmology, Hadassah Hebrew University Medical Center, Jerusalem 91120, Israel

Abstract

Presbyopia is often corrected by progressive soft contact lenses (CL), and the resulting visual acuity-based parameters can be affected by the lens design and pupil size under different lighting conditions. In this study, we examined the effect of CL design (spheric vs. aspheric) on objective parameters of visual acuity-based parameters under mesopic vs. photopic lighting conditions. In a prospective, double-blind study, pre-presbyopic and presbyopic patients were fitted with spheric (Dispo Silk; 8.6 base curve, 14.2 diameter) and aspheric (Dispo Aspheric; 8.4 base curve, 14.4 diameter) CLs. The low contrast (10%) and high contrast (100%) visual acuity (VA), amplitude of accommodation (AA) (push-away method, Diopters) and distance contrast sensitivity (CS) (FACT chart, cycles per degree (CPD)) were measured with both types of CLs under mesopic and photopic lighting conditions. The eye with the better visual acuity was tested and analyzed. Thirteen patients (age range: 38–45 years) were included. The mean CS was significantly better with spheric compared to aspheric lenses for low spatial frequencies (3 CPD: 81.69 ± 7.86, 67.62 ± 5.67, respectively; p < 0.05), though there was no significant difference for lower or higher spatial frequencies (1.5, 6, 12, 18 CPD). The low-contrast (10%) and high-contrast (100%) VAs were not different between the two lens designs. However, there were significant differences between near VA, distance low-contrast VA and AA obtained under mesopic (dim) vs. photopic (bright) conditions with the aspheric design correction modality. In conclusion, photopic lighting conditions improved both the visual acuity and measured amplitude of accommodation with both lens designs, though the amplitude of accommodation was significantly higher with aspheric lenses. However, contrast sensitivity demonstrated the superiority of the spheric lens at a 3 CPD spatial frequency. This suggests that the ideal lens differs from patient to patient, depending on the visual demands.

Publisher

MDPI AG

Subject

Cell Biology,Cognitive Neuroscience,Sensory Systems,Optometry,Ophthalmology

Reference38 articles.

1. The mechanism of presbyopia;Strenk;Prog. Retin. Eye Res.,2005

2. Effect of defocus on response time in different age groups: A pilot study;Vasudevan;J. Optom.,2016

3. United Nations Department of Economic, and Social Affairs, Population Division (2019). World Population Ageing 2019: Highlights, United Nations.

4. Objective and subjective visual performance of multifocal contact lenses: Pilot study;Vasudevan;Cont. Lens Anterior Eye,2014

5. Visual performance with simultaneous vision multifocal contact lenses;Clin. Exp. Optom.,2012

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3