Internal Tube Occlusion with An Easily Removable Non-Absorbable Double Suture: A Novel Surgical Technique Adjunct for Non-Valved Glaucoma Drainage Devices

Author:

Savastano Alfonso12ORCID,Gambini Gloria12,Savastano Maria Cristina12ORCID,Carlà Matteo Mario12ORCID,Rizzo Clara3,Caporossi Tomaso12ORCID,Crincoli Emanuele12ORCID,Rizzo Stanislao12

Affiliation:

1. Ophthalmology Unit, Fondazione Policlinico Universitario A. Gemelli IRCCS, 00168 Rome, Italy

2. Ophthalmology Unit, Catholic University “Sacro Cuore”, 00168 Rome, Italy

3. Ophthalmology Unit, Department of Surgery, University Hospital, 56100 Pisa, Italy

Abstract

To describe a surgical variant for non-valved glaucoma drainage device implants using an easily removable non-absorbable double suture into the lumen of the tube. A retrospective, non-comparative case series of 10 patients who underwent a non-valved glaucoma drainage device implant with an endoluminal double-suture for refractory glaucoma. The sutures were easily removed postoperatively without the need for an operating room. Intraocular pressure, number of medications, and early and late complications were evaluated with a follow-up of 12 months. None of the eyes that underwent an operation developed early or late complications. The first endoluminal suture was removed in all eyes with a mean time of removal of 30 ± 7 days. The second suture was removed in all eyes with a mean time of removal of 90 ± 7 days. No complications were noted, either, after or during suture removal. The mean preoperative IOP was 27.3 ± 4.0 and the postoperative IOP, at the end of the follow-up, was 12.7 ± 1.4. At the end of the follow-up, six patients (60%) achieved complete success and four patients (40%) achieved qualified success. In conclusion, in our case series, the surgical variant allowed for a safe and gradual regulation of the flow during postoperative management. Considering the efficacy of non-valved glaucoma drainage devices, an improvement in the safety profile allows surgeons to broaden the surgical indications.

Publisher

MDPI AG

Subject

Cell Biology,Cognitive Neuroscience,Sensory Systems,Optometry,Ophthalmology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3