Towards the Improvement of Soil Salinity Mapping in a Data-Scarce Context Using Sentinel-2 Images in Machine-Learning Models

Author:

Sirpa-Poma J. W.1ORCID,Satgé F.12,Resongles E.34,Pillco-Zolá R.2,Molina-Carpio J.2ORCID,Flores Colque M. G.4,Ormachea M.4,Pacheco Mollinedo P.1,Bonnet M.-P.1ORCID

Affiliation:

1. ESPACE-DEV, Univ Montpellier, IRD, Univ Antilles, Univ Guyane, Univ Réunion, 34093 Montpellier, France

2. Universidad Mayor de San Andrés, Instituto de Hidráulica e Hidrología, La Paz, Bolivia

3. HSM, Univ Montpellier, CNRS, IRD, 34093 Montpellier, France

4. Universidad Mayor de San Andrés, Instituto de Investigaciones Químicas, La Paz, Bolivia

Abstract

Several recent studies have evidenced the relevance of machine-learning for soil salinity mapping using Sentinel-2 reflectance as input data and field soil salinity measurement (i.e., Electrical Conductivity-EC) as the target. As soil EC monitoring is costly and time consuming, most learning databases used for training/validation rely on a limited number of soil samples, which can affect the model consistency. Based on the low soil salinity variation at the Sentinel-2 pixel resolution, this study proposes to increase the learning database’s number of observations by assigning the EC value obtained on the sampled pixel to the eight neighboring pixels. The method allowed extending the original learning database made up of 97 field EC measurements (OD) to an enhanced learning database made up of 691 observations (ED). Two classification machine-learning models (i.e., Random Forest-RF and Support Vector Machine-SVM) were trained with both OD and ED to assess the efficiency of the proposed method by comparing the models’ outcomes with EC observations not used in the models´ training. The use of ED led to a significant increase in both models’ consistency with the overall accuracy of the RF (SVM) model increasing from 0.25 (0.26) when using the OD to 0.77 (0.55) when using ED. This corresponds to an improvement of approximately 208% and 111%, respectively. Besides the improved accuracy reached with the ED database, the results showed that the RF model provided better soil salinity estimations than the SVM model and that feature selection (i.e., Variance Inflation Factor-VIF and/or Genetic Algorithm-GA) increase both models´ reliability, with GA being the most efficient. This study highlights the potential of machine-learning and Sentinel-2 image combination for soil salinity monitoring in a data-scarce context, and shows the importance of both model and features selection for an optimum machine-learning set-up.

Funder

Agropolis Fondation

Centre National d’Etudes Spatiales

IRD

Publisher

MDPI AG

Subject

Electrical and Electronic Engineering,Biochemistry,Instrumentation,Atomic and Molecular Physics, and Optics,Analytical Chemistry

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3