Abstract
Intramedullary nailing (IMN) is a popular treatment for elderly patients with femoral shaft fractures. Recently, prophylactic neck fixation has been increasingly used to prevent proximal femoral fractures during IMN. Therefore, this study aimed to investigate the biomechanical strength of prophylactic neck fixation in osteoporotic femoral fractures. An osteoporotic femur model was created to simulate the union of femoral shaft fractures with IMN. Two study groups comprising six specimens each were created for IMN with two standard proximal locking screws (SN group) and IMN with two reconstruction proximal locking screws (RN group). Axial loading was conducted to measure the stiffness, load-to-failure, and failure modes. There were no statistically significant differences in stiffness between the two groups. However, the load-to-failure in the RN group was significantly higher than that in the SN group (p < 0.05). Femoral neck fractures occurred in all specimens in the SN group. Five constructs in the RN group showed subtrochanteric fractures without femoral neck fractures. However, one construct was observed in both subtrochanteric and femoral neck fractures. Therefore, prophylactic neck fixation may be considered an alternative biomechanical solution to prevent proximal femoral fractures when performing IMN for osteoporotic femoral fractures.
Funder
National Research Foundation of Korea
Cited by
2 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献