High Electrode Impedance Values in Pediatric Cochlear Implant Recipients May Imply Insufficient Auditory and Language Skills Development

Author:

Brkic Faris F.ORCID,Umihanic Sekib,Harcinovic Alen,Piric Lejla,Brkic Fuad

Abstract

Background: Measurements of electrode impedance values are routinely performed after cochlear implantation. The primary objective of the study was to determine if pediatric, prelingually deafened patients with different postoperative performances showed significantly different impedance values one year after implantation. Methods: This study comprised 42 pediatric cochlear implant recipients provided with the device in a single academic tertiary referral center between 1 January 2000, and 31 December 2016. Medical chart analysis was performed in order to assess evolution of impedance values during the first postoperative year on a monthly basis. Electrode impedance values measurements one year postoperatively were compared between children with successful and unsuccessful auditory and language skills development assessed using the EARS protocol (a name of a performance test). Furthermore, values were compared among recipients of different implant types and among different cochlear segments. Results: A gradual rise of average impedance values was found during the first months of implant use (1st month, 7.32 kΩ; 3rd month, 7.86 kΩ) with the peak at the 4th postoperative month (7.96 kΩ), followed by a gradual decrease towards the 12th month (6th month, 7.62 kΩ; 12th month, 6.86 kΩ). Lower values at the 12th postoperative month were observed in recipients with successful development compared to patients presented with unsuccessful development (6.22 kΩ vs. 7.82 kΩ; p = 0.001). Mean impedance values were different when compared among cochlear segments and among different implant types. Conclusion: High electrode impedance values one year after implantation in pediatric patients may imply insufficient auditory and language skills development. Further studies are needed in order to validate our results.

Publisher

MDPI AG

Subject

General Medicine

Reference20 articles.

1. Effects of Electrode Array Length on Frequency-Place Mismatch and Speech Perception with Cochlear Implants

2. Impedance changes in cochlear implant users;Zadrozniak;Otolaryngol. Pol.,2011

3. Observation on the change of electrode impedance and THR/MCL values in 20 cases with Med-EL Combi 40+ cochlear implant;Wu;Lin Chung Er Bi Yan Hou Tou Jing Wai Ke Za Zhi,2013

4. Analysis of electrical thresholds and maximum comfortable levels in cochlear implant patients

5. Assessment of Auditory Skills in 140 Cochlear Implant Children Using the EARS Protocol