A Retrospective, Observational Study of Catheter-Associated Urinary Tract Infection Events Post-Implementation of a Novel Urinary Catheter System with Active Drain Line Clearance and Automated Intra-Abdominal Pressure Monitoring

Author:

Brockway PatrickORCID,Hill David M.ORCID,Moll VanessaORCID,Stanton KellyORCID,Malbrain Manu L. N. G.ORCID,Velamuri Sai R.

Abstract

Objective: A quality improvement study to assess catheter-associated urinary tract infection (CAUTI) rate post-implementation of a bladder catheter with integrated active drain line urine clearance and automated intra-abdominal pressure monitoring in a burn intensive care unit (ICU). DESIGN: Eight-year retrospective before and after study (2015–2022). Setting: A single American Burn Association-verified Burn Center with 14 inpatient beds. Patients: Patients meeting criteria for admission to a Burn Center. Methods: Retrospective cohort study following the implementation of a novel urine output monitoring system with integrated drain line and urine clearance. Data from a 48-month (from January 2015–December 2018) historical control (period 1) were compared to data from a 28-month (from January 2020 to April 2022) post-implementation period (period 2). Pre- and post-implementation CAUTI event incidences were compared. Patients were transferred from outside hospitals with gravity bladder. A distinction in the chart between catheter types was impossible. Charts were reviewed to characterize patients with CAUTI events. Results: A total of 42 CAUTIs in 2243 patients were identified using the National Health and Safety Network (NHSN) definition during the analyzed period. There were 40 CAUTI events in period 1 and two CAUTIs in period 2. The incidence of CAUTI events pre-implementation was 0.030 (mean of 10 CAUTI events per year) compared to 0.002 (mean of 1 CAUTI event per year) post-implementation of an automatic drain line clearing UO monitoring system showing a significant reduction in CAUTI events (p < 0.01, risk ratio novel vs. gravity bladder catheter 0.071, 95% confidence interval: 0.017–0.294). Conclusions: CAUTIs were reduced in the period following the implementation of a novel urinary catheter system with an integrated active drain line and urine clearance in burn patients.

Publisher

MDPI AG

Subject

Paleontology,Space and Planetary Science,General Biochemistry, Genetics and Molecular Biology,Ecology, Evolution, Behavior and Systematics

Reference41 articles.

1. National Healthcare Safety Network (NHSN) Patient Safety Component Manual (2022, June 06). Centers for Disease Control and Prevention Website, Available online: https://www.cms.gov/Medicare/Medicare-Fee-for-Service-Payment/HospitalAcqCond/Hospital-Acquired_Conditions.

2. Multistate point-prevalence survey of health care-associated infections;N. Engl. J. Med.,2014

3. Catheter associated urinary tract infections;Antimicrob. Resist. Infect. Control,2014

4. The attributable cost of catheter-associated urinary tract infections in the United States: A systematic review;Am. J. Infect. Control,2018

5. (2022, June 12). National Healthcare Safety Network (NHSN) Definition CAUTI Criteria, Available online: https://www.ahrq.gov/hai/quality/tools/cauti-ltc/modules/resources/tools/cauti-surveillance/pocket-card.html.

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3