A Retrospective, Observational Study of Catheter-Associated Urinary Tract Infection Events Post-Implementation of a Novel Urinary Catheter System with Active Drain Line Clearance and Automated Intra-Abdominal Pressure Monitoring

Author:

Brockway PatrickORCID,Hill David M.ORCID,Moll VanessaORCID,Stanton KellyORCID,Malbrain Manu L. N. G.ORCID,Velamuri Sai R.

Abstract

Objective: A quality improvement study to assess catheter-associated urinary tract infection (CAUTI) rate post-implementation of a bladder catheter with integrated active drain line urine clearance and automated intra-abdominal pressure monitoring in a burn intensive care unit (ICU). DESIGN: Eight-year retrospective before and after study (2015–2022). Setting: A single American Burn Association-verified Burn Center with 14 inpatient beds. Patients: Patients meeting criteria for admission to a Burn Center. Methods: Retrospective cohort study following the implementation of a novel urine output monitoring system with integrated drain line and urine clearance. Data from a 48-month (from January 2015–December 2018) historical control (period 1) were compared to data from a 28-month (from January 2020 to April 2022) post-implementation period (period 2). Pre- and post-implementation CAUTI event incidences were compared. Patients were transferred from outside hospitals with gravity bladder. A distinction in the chart between catheter types was impossible. Charts were reviewed to characterize patients with CAUTI events. Results: A total of 42 CAUTIs in 2243 patients were identified using the National Health and Safety Network (NHSN) definition during the analyzed period. There were 40 CAUTI events in period 1 and two CAUTIs in period 2. The incidence of CAUTI events pre-implementation was 0.030 (mean of 10 CAUTI events per year) compared to 0.002 (mean of 1 CAUTI event per year) post-implementation of an automatic drain line clearing UO monitoring system showing a significant reduction in CAUTI events (p < 0.01, risk ratio novel vs. gravity bladder catheter 0.071, 95% confidence interval: 0.017–0.294). Conclusions: CAUTIs were reduced in the period following the implementation of a novel urinary catheter system with an integrated active drain line and urine clearance in burn patients.

Publisher

MDPI AG

Subject

Paleontology,Space and Planetary Science,General Biochemistry, Genetics and Molecular Biology,Ecology, Evolution, Behavior and Systematics

Reference41 articles.

1. National Healthcare Safety Network (NHSN) Patient Safety Component Manual (2022, June 06). Centers for Disease Control and Prevention Website, Available online: https://www.cms.gov/Medicare/Medicare-Fee-for-Service-Payment/HospitalAcqCond/Hospital-Acquired_Conditions.

2. Multistate point-prevalence survey of health care-associated infections;N. Engl. J. Med.,2014

3. Catheter associated urinary tract infections;Antimicrob. Resist. Infect. Control,2014

4. The attributable cost of catheter-associated urinary tract infections in the United States: A systematic review;Am. J. Infect. Control,2018

5. (2022, June 12). National Healthcare Safety Network (NHSN) Definition CAUTI Criteria, Available online: https://www.ahrq.gov/hai/quality/tools/cauti-ltc/modules/resources/tools/cauti-surveillance/pocket-card.html.