The Quantification of Myocardial Fibrosis on Human Histopathology Images by a Semi-Automatic Algorithm

Author:

Gonciar Diana12,Berciu Alexandru-George3ORCID,Danku Alex Ede3ORCID,Lorenzovici Noemi3,Dulf Eva-Henrietta3ORCID,Mocan Teodora45,Nicula Sorina-Melinda6,Agoston-Coldea Lucia1

Affiliation:

1. 2nd Department of Internal Medicine, Iuliu Hațieganu University of Medicine and Pharmacy, 400012 Cluj-Napoca, Romania

2. Department of Pathology, Iuliu Hațieganu University of Medicine and Pharmacy, 400012 Cluj-Napoca, Romania

3. Automation Department, Faculty of Automation and Computer Science, Energy Transition Research Center, Technical University of Cluj-Napoca, 400114 Cluj-Napoca, Romania

4. Physiology Department, Iuliu Hațieganu University of Medicine and Pharmacy, 400012 Cluj-Napoca, Romania

5. Department of Nanomedicine, Regional Institute of Gastroenterology and Hepatology, 400158 Cluj-Napoca, Romania

6. Department of Pathology, Săcele Municipal Hospital, 505600 Săcele, Romania

Abstract

(1) Background: Considering the increasing workload of pathologists, computer-assisted methods have the potential to come to their aid. Considering the prognostic role of myocardial fibrosis, its precise quantification is essential. Currently, the evaluation is performed semi-quantitatively by the pathologist, a method exposed to the issues of subjectivity. The present research proposes validating a semi-automatic algorithm that aims to quantify myocardial fibrosis on microscopic images. (2) Methods: Forty digital images were selected from the slide collection of The Iowa Virtual Slidebox, from which the collagen volume fraction (CVF) was calculated using two semi-automatic methods: CIELAB-MATLAB® and CIELAB-Python. These involve the use of color difference analysis, using Delta E, in a rectangular region for CIELAB-Python and a region with a random geometric shape, determined by the user’s cursor movement, for CIELAB-MATLAB®. The comparison was made between the stereological evaluation and ImageJ. (3) Results: A total of 36 images were included in the study (n = 36), demonstrating a high, statistically significant correlation between stereology and ImageJ on the one hand, and the proposed methods on the other (p < 0.001). The mean CVF determined by the two methods shows a mean bias of 1.5% compared with stereology and 0.9% compared with ImageJ. Conclusions: The combined algorithm has a superior performance compared to the proposed methods, considered individually. Despite the relatively small mean bias, the limits of agreement are quite wide, reflecting the variability of the images included in the study.

Publisher

MDPI AG

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3