Abstract

A significant gap in the known methods for assessing the levels of metal artifacts in X-ray computed tomography and approaches to their reduction is an almost complete disregard for the physical nature of this artifact—the proximity to zero of radioscopic transparency. The proposed work fills this gap. A mathematical model has been developed for evaluating metal artifacts in X-ray computed tomography as applied to the geometry of a parallel beam. The simulation model was transformed into an algorithm, and a Mathcad program was designed to simulate images of the internal structure of the test objects. The algorithm for estimating the studied artifact includes the stages of generating sinograms and estimating the distributions of the linear coefficient over the sections of the object based on the back projection method with filtering. The efficiency of the metal artifacts simulation algorithm is demonstrated in the example of symmetric and asymmetric objects with low- and high-density inclusions and inclusions from materials with high atomic number values. The possibility of reducing metal artifacts with the help of a rational choice of the maximum energy of X-ray radiation and the ADC bit depth is illustrated. For example, for an aluminum cylinder 200 mm in diameter with a central cylindrical cavity 80 mm in diameter, cylindrical inserts 12 mm in diameter with material densities from 1.5 g/cm3 to 10 g/cm3, and effective atomic numbers of materials from 13 to 47, the numerical simulation method proved the following: it is practically unattainable to significantly reduce the level of metal artifacts by increasing the ADC capacity to the maximum X-ray energy of 160 keV; the desired effect is achieved by simultaneously increasing the maximum X-ray energy to 225 keV and the ADC capacity to 24 or 32; increasing the maximum X-ray energy from 160 keV to 225 keV leads to an increase in the energy absorbed in the material of the test object by 26%. The results of this research can be used at the design stage of X-ray computed tomography systems designed to control objects with fragments of low radiation transparency.

Funder

Ministry of Science and Higher Education of the Russian Federation

Publisher

MDPI AG

Subject

Fluid Flow and Transfer Processes,Computer Science Applications,Process Chemistry and Technology,General Engineering,Instrumentation,General Materials Science

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3