Effect of the Lateral Bone Augmentation Procedure in Correcting Peri-Implant Bone Dehiscence Defects: A 7-Years Retrospective Study

Author:

Hadzik Jakub1ORCID,Błaszczyszyn Artur1,Gedrange Tomasz2,Dominiak Marzena1

Affiliation:

1. Department of Dental Surgery, Faculty of Medicine and Dentistry, Medical University of Wrocław, 50-425 Wrocław, Poland

2. Department of Orthodontics, TU Dresden, 01069 Dresden, Germany

Abstract

Guided bone regeneration (GBR) is a well-documented and widely-used dental surgical procedure for the treatment of various types of alveolar bone defects. The aim of the study was to evaluate the long-term effectiveness of the GBR procedure in correcting small peri-implant bone dehiscence using the xenogeneic deproteinized bovine bone mineral material and a xenogeneic native bilayer collagen membrane. The present study was designed as a retrospective study. Seventy-five bone-level tapered two-piece dental implants Conelog®, Camlog (Biotechnologies AG, Switzerland) were divided into two groups G1—no bone augmentation (no GBR)—44 implants and G2—bone augmentation (GBR)—31 implants. For both groups, the closed healing protocol with a primary wound closure was used. The incidence of peri-implantits was evaluated, the quantitative assessment of soft tissue thickness was performed using the ultrasound (USG) device, quantitative assessment of marginal bone loss (MBL) was done. The prevalence of peri-implantitis was 5.3%, with a three-fold increase in peri-implantitis comparing the groups without and with bone augmentation (G1 = 2.27%, G2 = 9.7%). The average keratinized gingiva thickness was 1.87 mm and did not differ significantly between groups. No statistically significant differences in MBL between G1 and G2 were found. When dividing patients by gender, no statistically significant differences were observed. When dividing patients by age groups, statistically significant differences were observed between the youngest and oldest groups of patients. Within the limitations of this study, it can be concluded that the use of xenogeneic bone and a xenogeneic collagen membrane in a GBR procedure can be recommended to correct small peri-implant bone dehiscence.

Publisher

MDPI AG

Subject

Fluid Flow and Transfer Processes,Computer Science Applications,Process Chemistry and Technology,General Engineering,Instrumentation,General Materials Science

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3