Glassy Carbon Electrode Modified with CB/TiO2 Layer for Sensitive Determination of Sumatriptan by Means of Voltammetry and Flow Injection Analysis

Author:

Smajdor Joanna1ORCID,Paczosa-Bator Beata1ORCID,Grabarczyk Małgorzata2ORCID,Piech Robert1ORCID

Affiliation:

1. Department of Analytical Chemistry and Biochemistry, Faculty of Materials Science and Ceramics, AGH University of Science and Technology, Al. Mickiewicza, 30-059 Krakow, Poland

2. Department of Analytical Chemistry, Institute of Chemical Sciences, Faculty of Chemistry, Maria Curie-Sklodowska University, Maria Curie-Sklodowska Sq. 3, 20-031 Lublin, Poland

Abstract

Sumatriptan is an organic chemical compound from the tryptamine group. It is used as a medicine for migraine attacks and in the treatment of cluster headaches. In this work, a new voltammetric method is proposed for highly sensitive SUM determination, using glassy carbon electrodes modified with carbon black and titanium dioxide suspension. The novelty of the presented work is the usage of the mixture of carbon black and TiO2 as glassy carbon electrode modifier for the first time for SUM determination. The mentioned sensor was characterized by great repeatability and sensitivity of measurements, which resulted in the obtention of a wide range of linearity and a low detection limit. The electrochemical properties of the CB-TiO2/GC sensor was characterized using the LSV and EIS method. The effect of different factors on the SUM peak, such as supporting electrolyte type, preconcentration time and potential, or influence of interferents, were tested using the square wave voltammetry technique. The linear voltammetric response for the analyte was obtained in the concentration range of 5 nmol L−1 to 150 μmol L−1 with a detection limit of 2.9 nmol L−1 for a preconcentration time of 150 s in the 0.1 mol L−1 phosphate buffer pH 6.0. The proposed method was successfully applied for highly sensitive sumatriptan determination in complex matrices, such as tablets, urine, and plasma, with a good recovery parameter (94–105%). The presented CB-TiO2/GC electrode is characterized by great stability, it was used for 6 weeks without significant changes in the SUM peak current. Amperometric and voltammetric measurements of SUM under the flow injection conditions were also performed to indicate the possibility of its fast and accurate determination with a time of single analysis of approx. 30 s.

Funder

Excellence initiative-research university

Publisher

MDPI AG

Subject

Electrical and Electronic Engineering,Biochemistry,Instrumentation,Atomic and Molecular Physics, and Optics,Analytical Chemistry

Reference37 articles.

1. Migraine diagnosis and treatment: Results from the American Migraine Study II;Lipton;Headache J. Head Face Pain,2001

2. Pathophysiology of migraine;Pietrobon;Annu. Rev. Physiol.,2013

3. Migraine with aura and migraine without aura: An epidemiological study;Rasmussen;Cephalalgia,1992

4. Chronic migraine;Schwedt;BMJ,2014

5. Neurotology of migraine;Baloh;Headache J. Head Face Pain,1997

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3