Abstract
This study suggests a methodology for the decision of water quality measurement locations in order to identify water quality problems within a pipe network system under abnormal conditions. A water supply system conversion due to the occurrence of tank or pump problems between water supply zones was set as a possible abnormal scenario and the water flow direction sensitivity of the pipeline was quantified to estimate the water quality monitoring priority. The proposed methodology was applied to a new city, A, in South Korea, and the results are analyzed in detail and presented. The proposed methodology can be used as a method to select water quality monitoring points when establishing an operation plan for emergency link pipes. It is also expected that it can be applied in the evaluation of the adequacy of the previously established emergency link pipe operation plan.
Funder
National Research Foundation of Korea
Subject
Fluid Flow and Transfer Processes,Computer Science Applications,Process Chemistry and Technology,General Engineering,Instrumentation,General Materials Science
Cited by
6 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献