A Long-Term Split-Mouth Randomized Controlled Trial to Assess Implant Treatment Outcome Using Implants with a Different Surface Roughness

Author:

Glibert Maarten1ORCID,Matthys Carine2,Van Lancker Aurélie3,Segers Amber3,De Bruyn Hugo14ORCID

Affiliation:

1. Department of Periodontology and Oral Implantology, Faculty of Medicine and Health Sciences, Oral Health Sciences, Ghent University, C. Heymanslaan 10, B-9000 Ghent, Belgium

2. Department of Reconstructive Dentistry, Faculty of Medicine and Health Sciences, Oral Health Sciences, Ghent University, C. Heymanslaan 10, B-9000 Ghent, Belgium

3. Faculty of Medicine and Health Sciences, Oral Health Sciences, Ghent University, C. Heymanslaan 10, B-9000 Ghent, Belgium

4. Department of Periodontology, Academic Centre for Dentistry Amsterdam (ACTA), Gustav Mahlerlaan 3004, 1081 LA Amsterdam, The Netherlands

Abstract

The influence of implant surface roughness on implant treatment outcome is still under debate. A rougher implant surface improves osseointegration but yields greater plaque accumulation and biofilm formation. Hybrid implants have a minimally rough component coronally and a moderately rough implant body. The aim of this split-mouth study is to evaluate the long-term outcome of treatment with hybrid and moderately rough implants after 6 years. As a secondary aim, Oral Health Quality of Life (OHQoL) was assessed after one and six years. Fully edentulous patients received an overdenture supported by two implants. One implant had a hybrid surface (MSC) and one implant had a moderately rough surface (DCC). Radiographic crestal bone loss (CBL), plaque score, bleeding on probing (BoP) and periodontal probing depth (PPD) were determined at one and six years. OHQoL was evaluated using the Oral Health Impact Profile-14 (OHIP-14) questionnaire and a Visual Analogue Scale (VAS). Twenty-one patients with 42 implants were evaluated after 6 years. No implants failed and a mean CBL of 0.26 mm (SD: 0.42) for the MSC group and 0.17 mm (SD: 0.29) for the DCC group was observed, which was not statistically significant. Periodontal parameters were comparable after 6 years and a significant improvement in OHQoL was observed. This randomized controlled trial concludes that hybrid implants are a predictable treatment alternative for moderately rough implants in patients with an overdenture supported by two implants.

Funder

Southern Implants

Publisher

MDPI AG

Reference35 articles.

1. The mandibular complete overdenture;Burns;Dent. Clin. N. Am.,2004

2. British Society for the Study of Prosthetic Dentistry (2009). The York consensus statement on implant-supported overdentures. Eur. J. Prosthodont. Restor. Dent., 17, 164–165.

3. Management of Edentulous Patients;Lee;Dent. Clin. N. Am.,2019

4. A comparative evaluation of chewing efficiency, masticatory bite force, and patient satisfaction between conventional denture and implant-supported mandibular overdenture: An in vivo study;Sharma;J. Indian Prosthodont. Soc.,2017

5. Implant Surface Material, Design, and Osseointegration;Ogle;Dent. Clin. N. Am.,2015

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3