Intra-Reliability of a Wearable Near-Infrared Sensor for Monitoring the Intensity of Exercise

Author:

Michalik Kamil1ORCID,Smolarek Marcin1ORCID,Nowak Michał2,Pueo Basilio3ORCID,Żmijewski Piotr4

Affiliation:

1. Department of Human Motor Skills, Faculty of Physical Education and Sport, Wroclaw University of Health and Sport Sciences, 51-612 Wroclaw, Poland

2. Collegium Medicum Dr. Władysław Biegański, Department of Physical Culture Sciences, Jan Długosz University, 42-200 Częstochowa, Poland

3. Research Group in Health, Physical Activity, and Sports Technology (Health-Tech), Faculty of Education, University of Alicante, 03690 San Vicente del Raspeig, Spain

4. Faculty of Physical Education, Gdansk University of Physical Education and Sport, 80-836 Gdansk, Poland

Abstract

The Q-LAC analyzer, a portable device employing near-infrared spectroscopy (NIRS), was designed to measure muscle oxygen saturation (SmO2) during physical exercise. This study aimed to assess the reliability of the Q-LAC analyzer in determining SmO2 levels during incremental cycling exercise. Thirteen physically active males (age 28.1 ± 5.3 y; height 181.2 ± 5.7 cm; body mass 79.9 ± 11.1 kg; BMI 24.2 ± 2.4 kg/m2) participated in this study. A submaximal incremental exercise test (SIET) on an electromagnetic cycle ergometer with a seven-day interval was performed twice. SmO2 levels in the vastus lateralis (VL) muscle of the dominant leg were simultaneously recorded using the Q-LAC device during both tests. The study calculated the intraclass correlation coefficient (ICC), the coefficient of variation (CV), the standard error of measurement (SEM), the smallest worthwhile change (SWC), and mean detectable change (MDC). A within-within-subjects ANOVA revealed no statistically significant effects for session (F1,12 = 0.97, p = 0.34, η2 = 0.07) and the interaction between session and workload (F4,48 = 0.19, p = 0.94, η2 = 0.02). ICC values ranged from 0.72 to 0.91. Furthermore, the analysis of CV, SEM, and SWC indicated that SmO2 measurements obtained with the Q-LAC device exhibit good reliability but marginal sensitivity. In conclusion, the portable Q-LAC analyzer provides consistent measurements of muscle oxygen saturation during low-to-moderate-intensity exercise on a cycle ergometer.

Publisher

MDPI AG

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3