Influence of Drilling Technique on the Radiographic, Thermographic, and Geomorphometric Effects of Dental Implant Drills and Osteotomy Site Preparations

Author:

Fraguas de San José Lara,Ruggeri Filippo Maria,Rucco Roberta,Zubizarreta-Macho ÁlvaroORCID,Alonso Pérez-Barquero Jorge,Riad Deglow Elena,Hernández Montero Sofía

Abstract

The aim of this comparative study is to analyze the influence of drilling technique on the radiographic, thermographic, and geomorphometric effects of dental implant drills and osteotomy site preparations. One hundred and twenty osteotomy site preparations were performed on sixty epoxy resin samples using three unused dental implant drill systems and four drilling techniques performed with a random distribution into the following study groups: Group A: drilling technique performed at 800 rpm with irrigation (n = 30); Group B: drilling technique performed at 45 rpm without irrigation (n = 30); Group C: drilling technique performed at 45 rpm with irrigation (n = 30); and Group D: drilling technique performed at 800 rpm without irrigation (n = 30). The osteotomy site preparation morphologies performed by the 4.1 mm diameter dental implant drills from each study group were analyzed and compared using a cone beam computed tomography (CBCT) scan. The termographic effects generated by the 4.1 mm diameter dental implant drills from each study group were registered using a termographic digital camera and the unused and 4.1 mm diameter dental implant drills that were used 30 times from each study group were exposed to a micro computed tomography (micro-CT) analysis to obtain a Standard Tessellation Language (STL) digital files that determined the wear comparison by geomorphometry. Statistically significant differences were observed between the thermographic and radiographic results of the study groups (p < 0.001). The effect of cooling significatively reduced the heat generation during osteotomy site preparation during high-speed drilling; furthermore, osteotomy site preparation was not affected by the wear of the dental implant drills after 30 uses, regardless of the drilling technique.

Publisher

MDPI AG

Subject

General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3