Affiliation:
1. Laboratory of Reinforced Concrete and Seismic Design of Structures, Civil Engineering Department, School of Engineering, Democritus University of Thrace, 67100 Xanthi, Greece
2. Architectural Engineering Department, School of Engineering, Democritus University of Thrace, 67100 Xanthi, Greece
Abstract
Real-time structural health monitoring (SHM) and accurate diagnosis of imminent damage are critical to ensure the structural safety of conventional reinforced concrete (RC) and fiber-reinforced concrete (FRC) structures. Implementations of a piezoelectric lead zirconate titanate (PZT) sensor network in the critical areas of structural members can identify the damage level. This study uses a recently developed PZT-enabled Electro-Mechanical Impedance (EMI)-based, real-time, wireless, and portable SHM and damage detection system in prismatic specimens subjected to flexural repeated loading plain concrete (PC) and FRC. Furthermore, this research examined the efficacy of the proposed SHM methodology for FRC cracking identification of the specimens at various loading levels with different sensor layouts. Additionally, damage quantification using values of statistical damage indices is included. For this reason, the well-known conventional static metric of the Root Mean Square Deviation (RMSD) and the Mean Absolute Percentage Deviation (MAPD) were used and compared. This paper addresses a reliable monitoring experimental methodology in FRC to diagnose damage and predict the forthcoming flexural failure at early damage stages, such as at the onset of cracking. Test results indicated that damage assessment is successfully achieved using RMSD and MAPD indices of a strategically placed network of PZT sensors. Furthermore, the Upper Control Limit (UCL) index was adopted as a threshold for further sifting the scalar damage indices. Additionally, the proposed PZT-enable SHM method for prompt damage level is first established, providing the relationship between the voltage frequency response of the 32 PZT sensors and the crack propagation of the FRC prisms due to the step-by-step increased imposed load. In conclusion, damage diagnosis through continuous monitoring of PZTs responses of FRC due to flexural loading is a quantitative, reliable, and promising application.
Reference63 articles.
1. Reliability Assessment of Concrete under External Sulfate Attack;Sun;Case Stud. Constr. Mater.,2021
2. Degradation of Alkali-Activated Slag and Fly Ash Mortars under Different Aggressive Acid Conditions;Ren;J. Mater. Civ. Eng.,2021
3. Self-Healing Capacity of Fiber Reinforced Cementitious Composites. State of the Art and Perspectives;Cuenca;KSCE J. Civ. Eng.,2017
4. Martinelli, E., Lima, C., Pepe, M., Caggiano, A., and Faella, C. (2018, January 6–7). Post-Cracking Response of Hybrid Recycled/Industrial Steel Fiber-Reinforced Concrete. Proceedings of the SP-326: Durability and Sustainability of Concrete Structures (DSCS-2018), Moscow, Russia.
5. Behaviour of Macro-Synthetic Fibers Reinforced Concrete: Experimental, Numerical and Design Code Investigations;Nana;Structures,2021