Efficacy of PZT Sensors Network Different Configurations in Damage Detection of Fiber-Reinforced Concrete Prisms under Repeated Loading

Author:

Naoum Maria C.1ORCID,Papadopoulos Nikos A.1ORCID,Sapidis George M.1ORCID,Voutetaki Maristella E.2ORCID

Affiliation:

1. Laboratory of Reinforced Concrete and Seismic Design of Structures, Civil Engineering Department, School of Engineering, Democritus University of Thrace, 67100 Xanthi, Greece

2. Architectural Engineering Department, School of Engineering, Democritus University of Thrace, 67100 Xanthi, Greece

Abstract

Real-time structural health monitoring (SHM) and accurate diagnosis of imminent damage are critical to ensure the structural safety of conventional reinforced concrete (RC) and fiber-reinforced concrete (FRC) structures. Implementations of a piezoelectric lead zirconate titanate (PZT) sensor network in the critical areas of structural members can identify the damage level. This study uses a recently developed PZT-enabled Electro-Mechanical Impedance (EMI)-based, real-time, wireless, and portable SHM and damage detection system in prismatic specimens subjected to flexural repeated loading plain concrete (PC) and FRC. Furthermore, this research examined the efficacy of the proposed SHM methodology for FRC cracking identification of the specimens at various loading levels with different sensor layouts. Additionally, damage quantification using values of statistical damage indices is included. For this reason, the well-known conventional static metric of the Root Mean Square Deviation (RMSD) and the Mean Absolute Percentage Deviation (MAPD) were used and compared. This paper addresses a reliable monitoring experimental methodology in FRC to diagnose damage and predict the forthcoming flexural failure at early damage stages, such as at the onset of cracking. Test results indicated that damage assessment is successfully achieved using RMSD and MAPD indices of a strategically placed network of PZT sensors. Furthermore, the Upper Control Limit (UCL) index was adopted as a threshold for further sifting the scalar damage indices. Additionally, the proposed PZT-enable SHM method for prompt damage level is first established, providing the relationship between the voltage frequency response of the 32 PZT sensors and the crack propagation of the FRC prisms due to the step-by-step increased imposed load. In conclusion, damage diagnosis through continuous monitoring of PZTs responses of FRC due to flexural loading is a quantitative, reliable, and promising application.

Publisher

MDPI AG

Reference63 articles.

1. Reliability Assessment of Concrete under External Sulfate Attack;Sun;Case Stud. Constr. Mater.,2021

2. Degradation of Alkali-Activated Slag and Fly Ash Mortars under Different Aggressive Acid Conditions;Ren;J. Mater. Civ. Eng.,2021

3. Self-Healing Capacity of Fiber Reinforced Cementitious Composites. State of the Art and Perspectives;Cuenca;KSCE J. Civ. Eng.,2017

4. Martinelli, E., Lima, C., Pepe, M., Caggiano, A., and Faella, C. (2018, January 6–7). Post-Cracking Response of Hybrid Recycled/Industrial Steel Fiber-Reinforced Concrete. Proceedings of the SP-326: Durability and Sustainability of Concrete Structures (DSCS-2018), Moscow, Russia.

5. Behaviour of Macro-Synthetic Fibers Reinforced Concrete: Experimental, Numerical and Design Code Investigations;Nana;Structures,2021

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3