A Preliminary Investigation about the Influence of WIMU PROTM Location on Heart Rate Accuracy: A Comparative Study in Cycle Ergometer

Author:

Marzano-Felisatti Joaquín Martín1ORCID,De Lucca Leonardo2ORCID,Guzmán Luján José Francisco3ORCID,Priego-Quesada Jose Ignacio1ORCID,Pino-Ortega José4ORCID

Affiliation:

1. Research Group in Sports Biomechanics (GIBD), Department of Physical Education and Sports, Faculty of Physical Activity and Sport Sciences, Universitat de València, 46010 Valencia, Spain

2. Laboratory of Human Performance Research, Centre of Health and Sport Sciences, University of Santa Catarina State, Florianópolis 88040-900, Brazil

3. Research Group in Sports Technique and Tactics (GITTE), Department of Physical Education and Sports, Faculty of Physical Activity and Sport Sciences, Universitat de València, 46010 Valencia, Spain

4. Biovetmed & Sportsci Research Group, Department of Physical Activity and Sport, Faculty of Sport Sciences, University of Murcia, 30720 San Javier, Spain

Abstract

Technological development has boosted the use of multi-sensor devices to monitor athletes’ performance, but the location and connectivity between devices have been shown to affect data reliability. This preliminary study aimed to determine whether the placement of a multi-sensor device (WIMU PROTM) could affect the heart rate signal reception (GARMINTM chest strap) and, therefore, data accuracy. Thirty-two physical education students (20 men and 12 women) performed 20 min of exercise in a cycle ergometer based on the warm-up of the Function Threshold Power 20 test in laboratory conditions, carrying two WIMU PROTM devices (Back: inter-scapula; Bicycle: bicycle’s handlebar—20 cm from the chest) and two GARMINTM chest straps. A one-dimensional statistical parametric mapping test found full agreement between the two situations (inter-scapula vs. bicycle’s handlebar). Excellent intra-class correlation values were obtained during the warm-up (ICC = 0.99, [1.00–1.00], p < 0.001), the time trial test (ICC = 0.99, [1.00–1.00], p < 0.001) and the cool-down (ICC = 0.99, [1.00–1.00], p < 0.001). The Bland–Altman plots confirmed the total agreement with a bias value of 0.00 ± 0.1 bpm. The interscapular back placement of the WIMU PROTM device does not affect heart rate measurement accuracy with a GARMINTM chest strap during cycling exercise in laboratory conditions.

Funder

Ministry of Universities of Spain

Coordination for the Improvement of Higher Education Personnel of Brazil

Publisher

MDPI AG

Subject

Electrical and Electronic Engineering,Biochemistry,Instrumentation,Atomic and Molecular Physics, and Optics,Analytical Chemistry

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3