Accuracy of Proximal and Occlusal Contacts of Single Implant Crowns Fabricated Using Different Digital Scan Methods: An In Vitro Study

Author:

Ren Xi,Son KeunbadaORCID,Lee Kyu-Bok

Abstract

The purpose of this in vitro study was to compare the accuracy of the proximal and occlusal contacts of single implant crowns fabricated with four data capture methods. The resin models were mounted on an articulator, digitized using a laboratory scanner, and saved as a standard tessellation language (STL) file to serve as the master reference model (MRM). Two different intraoral scan body (ISB) systems were evaluated: polyetheretherketone (PEEK) short scan body (SSB) and PEEK long scan body (LSB) (n = 12). The digital impressions (SSB and LSB) were acquired using an intraoral scanner with ISB. Two different conventional techniques were also evaluated: PEEK short scan body with coping plastic cap (CPC) and pick-up coping (PUC) (n = 12). The implant impressions (CPC and PUC) were recorded using a conventional impression technique. The crown and abutment were fabricated with a milling machine and then placed on the resin model and scanned using a laboratory scanner. The scanned files were saved as STL files to serve as test datasets. The MRM and test datasets were superimposed, and the mesial, distal, and occlusal distances were calculated using a 3D inspection software and statistically analyzed using the Kruskal–Wallis H test (α = 0.05). The direct data capture group had more accurate contact points on the three surfaces, with mesial contact of 64.7 (12.8) µm followed by distal contact of 65.4 (15) µm and occlusal contact of 147 (35.8) µm in the SSB group, and mesial contact of 84.9 (22.6) µm followed by distal contact of 69.5 (19.2) µm and occlusal contact of 115.9 (27.7) µm in the LSB group (p < 0.001). The direct data capture groups are closer to the ideal proximal and occlusal contacts for single implant crowns than the indirect data capture groups. There was no difference in the accuracy between the two types of scan body (SSB and LSB).

Funder

Ministry of Trade, Industry and Energy(MOTIE) and Korea Institute for Advancement of Tech-nolog

Publisher

MDPI AG

Subject

General Materials Science

Reference37 articles.

Cited by 9 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3