Fabrication of an Azithromycin Sensor

Author:

Niyitanga Theophile1,Khan Mohd Quasim2,Ahmad Khursheed1ORCID,Khan Rais Ahmad3ORCID

Affiliation:

1. School of Materials Science and Engineering, Yeungnam University, Gyeongsan 38541, Republic of Korea

2. Department of Chemistry, M.M.D.C, Moradabad, M.J.P. Rohilkhand University, Bareilly 244001, UP, India

3. Department of Chemistry, College of Science, King Saud University, Riyadh 11451, Saudi Arabia

Abstract

Azithromycin (AZY) is a well-known top-prioritized antibiotic and is used by humans in strong concentrations. However, the side effects of the AZY antibiotic may cause some serious and significant damage to humans and the environment. Thus, there is a need to develop effective and sensitive sensors to monitor accurate concentrations of AZY. In the last decade, electrochemistry-based sensors have received enormous attention from the scientific community because of their high sensitivity, selectivity, cost-effectiveness, fast response, rapid detection response, simple fabrication, and working principle. It is important to mention that electrochemical sensors rely on the properties of electrode modifiers. Hence, the selection of electrode materials is of great significance when designing and developing efficient and robust electrochemical sensors. In this study, we fabricated an AZY sensor by utilizing a molybdenum disulfide/titanium aluminum carbide (MoS2@Ti3AlC2) composite as the electrode material. The MoS2@Ti3AlC2 composite was synthesized via a simple sonication process. The synthesized MoS2@Ti3AlC2 composite was characterized using a powder X-ray diffraction (XRD) method to examine the phase purity and formation of the MoS2@Ti3AlC2 composite. Scanning electron microscopy (SEM) was used to study the surface morphological features of the prepared MoS2@Ti3AlC2 composite, whereas energy dispersive X-ray spectroscopy (EDAX) was adopted to determine the elemental composition of the prepared MoS2@Ti3AlC2 composite. The glassy carbon (GC) electrode was modified with the prepared MoS2@Ti3AlC2 composite and applied as the AZY sensor. The sensing performance of the MoS2@Ti3AlC2 composite-modified GC electrode was studied using linear sweep voltammetry. The sensor demonstrated excellent performance when determining AZY and showed a good detection limit of 0.009 µM with a sensitivity of 6.77 µA/µM.cm2.

Funder

King Saud University, Riyadh, Saudi Arabia

Publisher

MDPI AG

Subject

Clinical Biochemistry,General Medicine,Analytical Chemistry,Biotechnology,Instrumentation,Biomedical Engineering,Engineering (miscellaneous)

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Nanostructured diamond sensors detect emerging contaminants;Recent Progress and Development on Nanostructures [Working Title];2024-09-06

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3