Abstract
Due to the energy transformation in buildings, the proportions of energy consumption for heating, ventilation and domestic hot water preparation (DHW) have changed. The latter component can now play a significant role, not only in the context of the annual heat demand, but also in the context of selecting the peak power of the heat source. In this paper, the comparison of chosen methods for its calculation is presented. The results show that for contemporary residential buildings, the peak power for DHW preparation can achieve the same or higher value as the peak power for heating and ventilation. For this reason, nowadays the correct selection of the peak power of a heat source for DHW purposes becomes more important, especially if it uses renewable energy sources, because it affects its size and so the investment cost and economic efficiency. It is also indicated that in modern buildings, mainly accumulative systems with hot water storage tanks should be taken into account because they are less sensitive to design errors (wrongly selected peak value in the context of the uncertainty of hot water consumption) and because they result in acceptable value of peak power for DHW in comparison to heating and ventilation.
Funder
Ministry of Science and Higher Education
Subject
Energy (miscellaneous),Energy Engineering and Power Technology,Renewable Energy, Sustainability and the Environment,Electrical and Electronic Engineering,Control and Optimization,Engineering (miscellaneous)
Cited by
7 articles.
订阅此论文施引文献