Abstract
Friction is an intensely studied feature in orthodontics, as the sliding mechanics approach remains one of the most utilized techniques in current practice, and the question of whether self-ligating brackets produce less friction than conventional brackets still stands. The objective of this study was to compare a self-ligating system with different closing mechanisms and a conventional system with different ligating mechanisms regarding their frictional properties. Laboratory measurements were performed using an advanced materials testing machine generating tensile strength and load at maximum Load values, which were statistically analyzed and compared. These two parameters have been associated with the frictional resistance generated at the archwire–bracket slot interface. Statistically significant results were obtained when comparing the active self-ligating brackets with the passive self-ligating (tensile strength mean 1.953, SD 0.4231; load at maximum moad mean 6.000, SD 1.3000) and conventional brackets (tensile strength mean 1.953, SD 0.4231; load at maximum load mean 6.000, SD 1.3000), as well as when comparing the passive self-ligating brackets with the conventional brackets (tensile strength mean 1.708, SD 0.8628; load at maximum load mean 5.254, SD 2.645). The active self-ligating brackets tended to produce more friction when compared to the passive self-ligating brackets but were similar to conventional brackets with stainless steel ligatures.
Subject
General Materials Science
Cited by
7 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献