Implementation of the Indoor Environmental Quality (IEQ) Model for the Assessment of a Retrofitted Historical Masonry Building

Author:

Piasecki MichałORCID,Radziszewska-Zielina ElżbietaORCID,Czerski Piotr,Fedorczak-Cisak MałgorzataORCID,Zielina MichałORCID,Krzyściak PawełORCID,Kwaśniewska-Sip PatrycjaORCID,Grześkowiak WojciechORCID

Abstract

Achieving a satisfactory level for indoor environments of historical buildings is an ongoing problem that needs to be solved due to a large demand for deep retrofits in the whole of Europe. The implementation of the indoor environmental quality index (IEQ) to predict an occupant’s satisfaction in thermo-modernized historical buildings is a new concept which is a response to existing needs. In this article, a relevant study is provided with the intention to evaluate the indoor environmental performance of retrofitting effects in historical buildings dating back to the years 1873–1878. Considering the historical character of the buildings, some of the cellar spaces were fitted out with an innovative internal insulation system of mineral sheets based on calcium silicate to prevent water vapor condensation and effectively limit mold growth. The IEQ methodology was applied for retrofitted and non-retrofitted spaces as a comparison. Four essential components of indoor quality are investigated: thermal comfort, indoor air quality, acoustic comfort, and visual quality. The results of sub-component indexes are calculated based on the measured indoor parameters and the specific sensory functions. This paper discusses the results of an indoor environmental analysis including a mycological air quality assessment with the newly developed IAQindex (fungal air contamination index), total volatile organic compound concentration (TVOC), CO2, and formaldehyde (HCHO) assessment, the evaluation energy-related thermal comfort, acoustic, and visual quality, of modernized spaces. A questionnaire survey study was additionally carried out among a building’s users intentioned to compare the accounts of satisfaction before and after the retrofitting process and also to compare “subjective” results with the one’s based on in situ tests. The retrofitting approach was proven to be effective in limiting the presence of molds and a significant difference in indoor environmental quality between thermally insulated and uninsulated spaces was observed and discussed.

Publisher

MDPI AG

Subject

Energy (miscellaneous),Energy Engineering and Power Technology,Renewable Energy, Sustainability and the Environment,Electrical and Electronic Engineering,Control and Optimization,Engineering (miscellaneous)

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3