Feasibility of Matrix-Matched Material for Determining Elements in Rice Flour by SN-ICP-MS and LA-ICP-MS

Author:

Kukusamude Chunyapuk1,Kongsri Supalak1,Tamklang Ratchadawan1,Taebunpakul Sutthinun2

Affiliation:

1. Nuclear Technology Research and Development Center (NTRDC), Thailand Institute of Nuclear Technology (Public Organization), 9/9 Moo 7, Saimoon, Ongkharak, Nakhon Nayok 26120, Thailand

2. Chemical Metrology and Biometry Department, National Institute of Metrology (Thailand), 3/4-5 Moo 3, Technothani, Klong Ha, Klong Luang, Pathum Thani 12120, Thailand

Abstract

The preparation of matrix-matched material for elemental quantitative analysis in rice flour matrix is proposed here for the first time as part of a feasibility study using the SN-ICP-MS and LA-ICP-MS methods. It was prepared via the spiking process in colloidal solution of rice flour with different levels of arsenic (As), cadmium (Cd) and lead (Pb), followed by drying in a climatic chamber. Comparative studies of the results on external calibration and gravimetric standard addition ICP-MS approaches through the use of calibration standard solutions were discussed. Method bias from the external calibration method was investigated, demonstrating the systematic effect arising from the sample matrix. Characterizing the concentration of measurands was then reasonably proposed using the gravimetric standard addition ICP-MS. Using powdered rice matrix reference material for ICP-MS calibration following acid digestion, the study showed a good agreement of recovery studies. A feasibility study of the LA-ICP-MS method as a direct solid analysis performed on the matrix-matched standard was then discussed. In the study, large fluctuation of signals was found for constructing calibration curve, generating poor linearity, especially for As and Pb, although yttrium (Y) as internal standard was applied. This might be ascribed to a limited microscale of homogeneity, and particularly laser-induced preferential evaporation of volatile elements. Using a number of measured data points, the mean and median were statistically recommended to improve precision. An attempt to use of similar matrix in both standard and sample is a critical point to consider to minimize the elemental fractionation effect. The proposed approach to prepare matrix-matched material could be a potential means for achieving elemental quantitation.

Funder

Thailand Institute of Nuclear Technology

Publisher

MDPI AG

Reference28 articles.

1. Direct determination of cadmium in rice flour by laser ablation-ICP-MS;Baba;J. Anal. At. Spectrom.,2003

2. (2023, March 20). CXS 193-1995; Codex Alimentarius, General Standard for Contaminants and Toxins in Food and Feed. Adopted in 1995. Revised in 1997, 2006, 2008, 2009. Amended in 2010, 2012, 2013, 2014, 2015, 2016, 2017, 2018, 2019, 2021, 2022, 2023. Available online: https://www.fao.org/fao-who-codexalimentarius/sh-proxy/en/?lnk=1&url=https%253A%252F%252Fworkspace.fao.org%252Fsites%252Fcodex%252FStandards%252FCXS%2B193-1995%252FCXS_193e.pdf.

3. (1999). Codex Alimentarius, Recommended Methods of Analysis and Sampling. Adopted in 1999. Amended 2015 (Standard No. CXS 234-1999).

4. (2006). Lead, Cadmium, Copper, Iron, and Zinc in Foods. Atomic Absorption Spectrophotometry after Dry Ashing (Standard No. AOAC Official Method: 999.11-2005(2006)).

5. (2015). Heavy Metals in Food. Inductively Coupled Plasma-Mass Spectrometry, First Action 2015 (Standard No. AOAC Official Method: 2015.01).

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献