Hydrogen Peroxide Electrochemical Sensor Based on Ag/Cu Bimetallic Nanoparticles Modified on Polypyrrole

Author:

Guan Yanxun12,Xu Fen1ORCID,Sun Lixian1ORCID,Luo Yumei1,Cheng Riguang1,Zou Yongjin1ORCID,Liao Lumin12,Cao Zhong3

Affiliation:

1. Guangxi Key Laboratory of Information Materials & Guangxi Collaborative Innovation Center for Structure and Properties for New Energy and Materials, School of Material Science and Engineering, Guilin University of Electronic Technology, Guilin 541004, China

2. School of Electronic Engineering and Automation, Guilin University of Electronic Technology, Guilin 541004, China

3. Hunan Provincial Key Laboratory of Materials Protection for Electric Power and Transportation, Changsha University of Science & Technology, Changsha 410114, China

Abstract

Due to the strong oxidizing properties of H2O2, excessive discharge of H2O2 will cause great harm to the environment. Moreover, H2O2 is also an energetic material used as fuel, with specific attention given to its safety. Therefore, it is of great importance to explore and prepare good sensitive materials for the detection of H2O2 with a low detection limit and high selectivity. In this work, a kind of hydrogen peroxide electrochemical sensor has been fabricated. That is, polypyrrole (PPy) has been electropolymerized on the glass carbon electrode (GCE), and then Ag and Cu nanoparticles are modified together on the surface of polypyrrole by electrodeposition. SEM analysis shows that Cu and Ag nanoparticles are uniformly deposited on the surface of PPy. Electrochemical characterization results display that the sensor has a good response to H2O2 with two linear intervals. The first linear range is 0.1–1 mM (R2 = 0.9978, S = 265.06 μA/ (mM × cm2)), and the detection limit is 0.027 μM (S/N = 3). The second linear range is 1–35 mM (R2 = 0.9969, 445.78 μA/ (mM × cm2)), corresponding to 0.063 μM of detection limit (S/N = 3). The sensor reveals good reproducibility (σ = 2.104), repeatability (σ = 2.027), anti-interference, and stability. The recoveries of the electrode are 99.84–103.00% (for 0.1–1 mM of linear range) and 98.65–104.80% (for 1–35 mM linear range). Furthermore, the costs of the hydrogen peroxide electrochemical sensor proposed in this work are reduced largely by using non-precious metals without degradation of the sensing performance of H2O2. This study provides a facile way to develop nanocomposite electrochemical sensors.

Funder

National Natural Science Foundation of China

Scientific Research and Technology Development Program of Guangxi

Guangxi key research and development program

Science Research and Technology Development project of Guilin

Guangxi Bagui Scholar Foundation

Guilin Lijiang Scholar Foundation

Guangxi Collaborative Innovation Centre of Structure and Property for New Energy and Materials

Guangxi Advanced Functional Materials Foundation and Application Talents Small Highlands

Chinesisch-Deutsche Kooperationsgruppe

Guangxi Key Laboratory of Sustainable Utilization of Plant Functional Substances

Publisher

MDPI AG

Subject

Electrical and Electronic Engineering,Biochemistry,Instrumentation,Atomic and Molecular Physics, and Optics,Analytical Chemistry

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3