Abstract
This study investigates geometric parameters of commercially available or recently published models of catalyst substrates for passenger vehicles and provides a numerical evaluation of their influence on heat-up behavior. Parameters considered to have a significant impact on the thermal economy of a monolith are: internal surface area, heat transfer coefficient, and mass of the converter, as well as its heat capacity. During simulation experiments, it could be determined that the primary role is played by the mass of the monolith and its internal surface area, while the heat transfer coefficient only has a secondary role. Furthermore, an optimization loop was implemented, whereby the internal surface area of a commonly used substrate was chosen as a reference. The lengths of the thin wall and high cell density monoliths investigated were adapted consecutively to obtain the reference internal surface area. The results obtained by this optimization process contribute to improving the heat-up performance while simultaneously reducing the valuable installation space required.
Subject
Energy (miscellaneous),Energy Engineering and Power Technology,Renewable Energy, Sustainability and the Environment,Electrical and Electronic Engineering,Control and Optimization,Engineering (miscellaneous)