Clinical Outcomes after Additional Dynamic Renal® Stent Implantation for Stent Recoil in Ostial Coronary Lesions

Author:

Abdulrahman Bachir,Mashayekhi Kambis,Tajti Péter,Ferenc Miroslaw,Valina Christian MarcORCID,Hochholzer Willibald,Neumann Franz-Josef,Nührenberg Thomas GeorgORCID

Abstract

Background: Interventional treatment of aorto-ostial coronary stenoses is limited by stent recoil and suboptimal angiographic results, leading to restenosis and frequent re-interventions. As a potential bail-out strategy for stent recoil, implantation of an additional stent to increase radial force has been reported. Thus, we sought to investigate clinical outcomes after additional implantation of a Dynamic Renal® stent (DRS), a non-coronary; bare-metal stent with very high radial force, in aorto-ostial coronary stenoses. Methods: Patients treated by implantation of DRSs for stent recoil in the ostial right coronary artery or the left main stem were identified from the hospital database. Baseline clinical and procedural characteristics were compared to patients who underwent re-intervention for in-stent-restenosis in similar segments by either implantation of conventional drug-eluting stents (DES) or paclitaxel-coated balloons (PCB). Clinical follow-ups were performed up to three years following re-intervention with the assessment of death, target lesion reintervention (TLR), and major adverse cardiac events (MACE) as a combination death, myocardial infarction and target vessel revascularization. Kaplan–Meier analyses were performed for event-free survival between the three groups. Results: Between 05/2013 and 07/2019, 28 patients underwent DRS implantation of aorto-ostial coronary lesions. In comparison with 49 patients with DES implantation and 29 patients undergoing PCB treatment, no relevant differences in baseline parameters were identified. Median follow-up was 714 days, with an available follow-up of >1 year after intervention in 82.1% of patients. In the entire study cohort at two years after re-intervention, the TLR rate was 16% (17 patients), the MACE rate 37% (39 patients), and all-cause mortality 9% (10 patients), with no significant differences between the three groups. Conclusions: DRS implantation for treating stent recoil of aorto-ostial coronary lesions resulted in a high rate of TLR, and was associated with similar risk for death and MACE compared to treatment of in-stent-restenosis with DES or PCB. Randomized, larger comparisons of contemporary DES in patients exclusively presenting with stent recoil are necessary to further define the efficacy and safety of this approach.

Publisher

MDPI AG

Subject

General Medicine

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3