Affiliation:
1. Electrical Engineering Department, Faculty of Engineering, Al-Baha University, Al-Baha 65528, Saudi Arabia
Abstract
This paper presents an improvement to the fault ride-through (FRT) capabilities for a wind turbine that employs a switched reluctance generator (SRG) using a dynamic voltage restorer (DVR). The wind turbine may be disconnected from the grid by voltage sag, swell, and faulty line voltage in the grid. To improve the stator voltage of an SRG during grid failures, the DVR is applied to inject voltage at the point of common coupling (PCC) into the grid voltage. A control strategy for the DVR based on fuzzy logic controller (FLC) is proposed in this study to improve the FRT capability and meet the grid codes while avoiding the disconnection of the turbine from the grid. MATLAB/SIMULINK simulation validated the effectiveness and performance of this approach under three test cases: balanced sag, unbalanced sag, and a single line-to-ground fault. In addition, the total harmonic distortions utilizing different controllers were compared in sag mode. Furthermore, the simulation results exhibited significant improvement in transient and steady-state response, thus verifying the effectiveness of the control strategy compared to traditional methods.
Funder
Deputyship for Research & Innovation, Ministry of Education in Saudi Arabia
Subject
Management, Monitoring, Policy and Law,Renewable Energy, Sustainability and the Environment,Geography, Planning and Development,Building and Construction
Reference36 articles.
1. Improved Control Strategy for DFIG Wind Turbines for Low Voltage Ride Through;Wu;Energies,2013
2. Gao, D.W., Muljadi, E., Tian, T., Miller, M., and Wang, W. (2016). Comparison of Standards and Technical Requirements of Grid-Connected Wind Power Plants in China and the United States, National Renewable Energy Lab. (NREL).
3. Robert, B., and Brown, E.B. (2023, May 19). United States of America Joint Report of the North American Electric Reliability, Available online: https://www.federalregister.gov/documents/2023/04/24/2023-08610/north-american-electric-reliability-corporation-joint-federal-state-task-force-on-electric.
4. Voltage control of switched reluctance generator using grasshopper optimization algorithm;Bahy;Int. J. Power Electron. Drive Syst. (IJPEDS),2020
5. Maximum Power Point Tracking in Grid Connected Wind Plant by Using Intelligent Controller and Switched Reluctance Generator;Rahmanian;IEEE Trans. Sustain. Energy,2017
Cited by
2 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献