Fusiform versus Saccular Intracranial Aneurysms—Hemodynamic Evaluation of the Pre-Aneurysmal, Pathological, and Post-Interventional State

Author:

Korte Jana12ORCID,Marsh Laurel M. M.23ORCID,Saalfeld Sylvia24ORCID,Behme Daniel25ORCID,Aliseda Alberto6ORCID,Berg Philipp27ORCID

Affiliation:

1. Department of Fluid Dynamics and Technical Flows, University of Magdeburg, 39106 Magdeburg, Germany

2. Research Campus STIMULATE, University of Magdeburg, 39106 Magdeburg, Germany

3. Department of Mechanical Engineering, George Mason University, Fairfax, VA 22030, USA

4. Department of Computer Science and Automation, Ilmenau University of Technology, 98693 Ilmenau, Germany

5. University Hospital Magdeburg, University of Magdeburg, 39106 Magdeburg, Germany

6. Department of Mechanical Engineering, University of Washington, Seattle, WA 98195, USA

7. Department of Medical Engineering, University of Magdeburg, 39106 Magdeburg, Germany

Abstract

Minimally-invasive therapies are well-established treatment methods for saccular intracranial aneurysms (SIAs). Knowledge concerning fusiform IAs (FIAs) is low, due to their wide and alternating lumen and their infrequent occurrence. However, FIAs carry risks like ischemia and thus require further in-depth investigation. Six patient-specific IAs, comprising three position-identical FIAs and SIAs, with the FIAs showing a non-typical FIA shape, were compared, respectively. For each model, a healthy counterpart and a treated version with a flow diverting stent were created. Eighteen time-dependent simulations were performed to analyze morphological and hemodynamic parameters focusing on the treatment effect (TE). The stent expansion is higher for FIAs than SIAs. For FIAs, the reduction in vorticity is higher (Δ35–75% case 2/3) and the reduction in the oscillatory velocity index is lower (Δ15–68% case 2/3). Velocity is reduced equally for FIAs and SIAs with a TE of 37–60% in FIAs and of 41–72% in SIAs. Time-averaged wall shear stress (TAWSS) is less reduced within FIAs than SIAs (Δ30–105%). Within this study, the positive TE of FDS deployed in FIAs is shown and a similarity in parameters found due to the non-typical FIA shape. Despite the higher stent expansion, velocity and vorticity are equally reduced compared to identically located SIAs.

Funder

Fulbright U.S. Student Program

German Federal Ministry of Education and Research within the Research Campus STIMULATE

German Research Foundation

Publisher

MDPI AG

Subject

General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3