Affiliation:
1. College of Civil Engineering, Anhui Jianzhu University, Hefei 230601, China
2. Anhui Urban and Rural Construction Fire Prevention and Disaster Prevention Research Institute, Hefei 230601, China
3. School of Environment and Energy Engineering, Anhui Jianzhu University, Hefei 230601, China
4. Safety and Security Science Group, Faculty of Technology, Policy and Management, Delft University of Technology, 2628 BX Delft, The Netherlands
Abstract
Commercial complexes integrate various business formats, and a fire outbreak can lead to widespread, continuous, and chain-reaction social disturbances, including severe casualties, economic losses, and social impacts. To deeply explore the characteristics and influencing factors of fire accidents in urban commercial complexes in China, this study first analyzed fire accident cases in commercial complexes that occurred from 2002 to 2022. Using mathematical statistics, the analysis examined the year and month of the accidents, their severity, and their causes to identify key risk factors associated with fire hazards in urban commercial complexes. Subsequently, based on the WSR methodology, an index system for assessing the influencing factors of fire accidents in commercial complexes was constructed, encompassing four aspects: personnel, equipment, environment, and management, including 11 cause indicators and 9 outcome indicators. Then, the Decision Experiment and Evaluation Laboratory Method (DEMATEL) was used to quantitatively analyze the relationships among influencing factors, combined with Interpretative Structural Modeling (ISM) to perform a hierarchical categorization of the factors and identify those critically influencing commercial complex fires. This research indicates that critical influencing factors include inadequate regulations, insufficient fire safety inspections, inadequate safety training, careless use of fire during operations, inadequate government supervision, illegal renovations, unimplemented corporate fire safety responsibilities, and poor routine maintenance and management. These results provide a theoretical reference for effectively preventing and controlling fires in commercial complexes.
Funder
Doctoral Research Initiation Fund of Anhui Jianzhu University
Anhui Provincial Department of Housing and Urban-Rural Development
Anhui Urban and Rural Construction Fire Prevention and Disaster Prevention Research Institute
Reference39 articles.
1. Case study of the evacuating functions of the fire fighting and rescue windows in large-scale commercial buildings;Li;Fire Sci. Technol.,2021
2. Wang, Y. (2019). Pseudo-Public Spaces in Chinese Shopping Malls: Rise, Publicness and Consequences, Routledge.
3. Ordos Municipal People’s Government Office (2023, November 20). Notice on the establishment of Dongsheng. District “6–13” Fire Accident Investigation Team, Available online: https://www.ordos.gov.cn/ordosml/ordoszf/202207/t20220725_3247764.html.
4. (2023, November 20). Security Management Network. Available online: https://www.safehoo.com/Case/Case/Blaze/202112/5659732.shtml.
5. BIM-based building fire emergency management: Combining building users’ behavior decisions;Ma;Autom. Constr.,2020