The Application of a Synthetic Biodegradable Temporizing Matrix in Extensive Burn Injury: A Unicenter Experience of 175 Cases

Author:

Tapking Christian1,Panayi Adriana C.1,Hundeshagen Gabriel1,Thomas Benjamin F.1ORCID,Gazyakan Emre1ORCID,Bliesener Bjoern1,Bigdeli Amir K.1ORCID,Kneser Ulrich1ORCID,Vollbach Felix H.12

Affiliation:

1. Department of Hand, Plastic and Reconstructive Surgery, Microsurgery, Burn Center, BG Unfallklinik Ludwigshafen, Hand and Plastic Surgery, University of Heidelberg, 67071 Ludwigshafen, Germany

2. Division of Hand, Plastic and Aesthetic Surgery, Ludwig-Maximilians-University (LMU), 80539 Munich, Germany

Abstract

Objectives: Addressing extensive and deep burn wounds poses considerable challenges for both patients and surgeons. The NovoSorb® Biodegradable Temporizing Matrix (BTM) emerged as a novel dermal substitute and has been subjected to evaluation in large burn wound cases, with a specific focus on identifying risk factors associated with suboptimal take rates. Methods: All patients with burn wounds greater than 10% body surface that underwent BTM treatment between March 2020 and November 2023 were eligible for inclusion. Univariate analyses and linear regression models were employed to discern risk factors and predictors influencing the take rates of both the BTM and split-thickness skin grafts (STSGs). Results: A total of 175 patients (mean age 56.2 ± 19.8 years, 70.3% male) were evaluated. The mean take rates of the BTM and STSGs were 82.0 ± 24.7% and 87.3 ± 19.0%, respectively. There were significant negative correlations between BTM take and the number of surgeries before BTM application (r = −0.19, p = 0.01), %TBSA and STSG take (r = −0.36, p = <0.001) and significant positive correlations between BTM and STSG take (r = 0.41, p ≤ 0.001) in addition to NPWT and STSG take (r = 0.21, p = 0.01). Multivariate regression analyses showed that a larger number of surgeries prior to BTM application (OR −3.41, 95% CI −6.82, −0.03, p = 0.04) was associated with poorer BTM take. Allograft treatment before BTM application (OR −14.7, 95% CI −23.0, −6.43,p = 0.01) and failed treatment with STSG before BTM application (OR −20.8, 95% CI −36.3, −5.23, p ≤ 0.01) were associated with poorer STSG take, whereas higher BTM take rates were associated with overall higher STSG take (OR −0.15, 95% 0.05, 0.26, p = 0.01). The Meek technique was used in 24 patients and showed similar take rates (BTM: 76.3 ± 28.0%, p = 0.22; STSG: 80.7 ± 21.1, p = 0.07). Conclusions: This study summarizes our findings on the application of a BTM in the context of large burn wounds. The results demonstrate that successful treatment can be achieved even in patients with extensive burns, resulting in satisfying take rates for both the BTM and STSG. The data underscore the importance of promptly applying a BTM to debrided wounds and indicate good results when using Meek.

Publisher

MDPI AG

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3