Relationship between Pelvic Dimensions and Maximum Traction Forces Required during Parturition in Holstein Cows Using a Biomechanical Obstetric Simulator

Author:

Tsaousioti Angeliki1ORCID,Praxitelous Anastasia1ORCID,Patsikas Michail2,Becker Meik3,Bollwein Heinrich4ORCID,Boscos Constantin M.1ORCID,Kiossis Evangelos1,Tsousis Georgios1ORCID

Affiliation:

1. Clinic of Farm Animals, School of Veterinary Medicine, Faculty of Health Sciences, Aristotle University of Thessaloniki, 54627 Thessaloniki, Greece

2. Laboratory of Diagnostic Imaging, School of Veterinary Medicine, Faculty of Health Sciences, Aristotle University of Thessaloniki, 54627 Thessaloniki, Greece

3. Clinic for Cattle, University of Veterinary Medicine Hannover, 30559 Hannover, Germany

4. Clinic of Reproductive Medicine, Vetsuisse Faculty, University of Zurich, 8057 Zurich, Switzerland

Abstract

The primary aim of this study was to investigate the effect of the pelvic dimensions of Holstein cows on the traction forces during parturition. Additionally, the relationship between calf measurements and traction forces was explored. For this purpose, a modified in vitro biomechanical model simulating obstetric tractions was used. For the requirements of the experiment, six bone pelvises of deceased Holstein cows were collected based on their estimated pelvic inlet area (EPA) and prepared. Additionally, six stillborn calves were collected based on their body weight (BW). The parameters of the pelvic inlet and cavity were measured using computed tomography (CT). Using the simulator, every calf was pulled in a random order through all pelvises, realizing a total of 36 obstetrical tractions, and the required forces were documented with appropriate software. In each extraction, three peaks of forces were recorded, with the first peak occurring at the entrance of the elbows into the maternal pelvic cavity, the second peak at the entrance of the thorax, and the third at the entrance of the calf’s pelvis. Logistic regression revealed an exponential relationship between pelvic parameters and traction forces for the entrance of the elbows and the pelvis, with the recorded forces being higher in the two smallest pelvises and stabilizing at a lower level thereafter, while for the entrance of the thorax, the correlations were either exponential or linear. The adjusted coefficients of determination (r2) were generally above the threshold of 0.5 for the entrance of the elbows and pelvis and lower (0.3–0.4) regarding the thorax and were statistically significant (p < 0.05) in all cases. Regarding the relationships between the calf dimensions and the required traction forces, the types of correlations were primarily linear and of lower magnitude. The combination of pelvic and calf parameters in a multivariate model resulted in an r2 of 0.72 for the entrance of the elbows using the pelvic diagonal and calf’s body weight, an r2 of 0.62 using the pelvic area and calf’s thoracic circumference, and an r2 of 0.75 using the pelvic diagonal and calf’s fetlock joint width. In conclusion, under the conditions of the present experimentation, the applied traction forces were mainly influenced by the pelvic dimensions in an exponential manner, whereas the calf body measurements showed a weaker effect. Based on these findings, critical cut-off points exist, different for every pelvic parameter, below which a significant increase in the required traction forces is expected.

Funder

Greece and the European Union

Publisher

MDPI AG

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3