Skin Absorbed Dose Coefficients for Human Legs from Beta Radiation as a Function of Height

Author:

Yosofvand Mohammad1ORCID,Dhakal Rabin1ORCID,Nejat Ali2ORCID,Moussa Hanna3ORCID

Affiliation:

1. Department of Mechanical Engineering, Texas Tech University, Lubbock, TX 79409, USA

2. Department of Civil and Environmental Engineering, Texas Tech University, Lubbock, TX 79409, USA

3. Department of Physics and Astronomy, Texas Tech University, Lubbock, TX 79409, USA

Abstract

External exposure to skin from beta-emitter radionuclides following severe reactor accidents or nuclear testing can result in beta burning and other health complications. The skin absorbed dose coefficient (SADC) measures the energy deposition into the skin during such accidents. The U.S. Environmental Protection Agency has published several reports to measure the possible energy deposition into the skin in such accidents. However, the most recent SADC published by Federal Guidance Report (FGR) 12 was computed only at one meter above the contaminated surface. Therefore, it was necessary to develop a model to estimate the absorbed dose coefficients for skin at different heights. In this manuscript, Geant4, a Monte Carlo simulator toolkit, was used to estimate the absorbed dose coefficients from electron sources located on the soil surface with energies ranging from 0.1 to 4 MeV. The energy deposited from primary electrons, secondary electrons, and photons in a 50 µm thick layer of epidermis tissue (Basal Cells Layer) located at a depth of 50 µm from the skin surface was estimated at several discrete heights of human leg phantom. More than 40% of the total energy deposited comes from secondary electrons and photons in energy sources of 0.1 and 0.2 MeV on average, but for higher energies, this percentage is less than 1%, which indicates primary electrons are the main source of the deposited energy in the skin. Furthermore, the results showed the energy deposited into skin closer to the ground was 50–100% higher than the previously estimated doses for 1 m above the ground. The results from Geant4 showed a great correlation (R2 = 0.972) with the FGR 12 data at one meter height, and they were aligned with the published values from FGR 12, which validated the simulation results. Therefore, the calculated dose coefficients for different energy sources and different heights could be used in radiation protection measurements.

Publisher

MDPI AG

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3